Diagnosis Procedure
- CHECK FUSES
Check if any of the following fuses are blown:
FUSE LISTSignal name Fuse No. Ignition power supply 46 Is the inspection result normal?
YES: GO TO 2.
NO: Replace the blown fuse after repairing the affected circuit if a fuse is blown.
- CHECK ADAS CONTROL UNIT POWER SUPPLY CIRCUIT
Check voltage between ADAS control unit harness connector and ground.
VOLTAGE REFERENCE CHARTTerminal Condition Voltage (Approx.) (+) (-) ADAS control unit Ground Ignition switch Connector Terminal B50 16 OFF 0 V ON Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: Repair the ADAS control unit power supply circuit.
- CHECK ADAS CONTROL UNIT GROUND CIRCUIT
- Turn the ignition switch OFF.
- Disconnect the ADAS control unit connector.
- Check for continuity between ADAS control unit harness connector and ground.CONTINUITY REFERENCE CHART
ADAS control unit Ground Continuity Connector Terminal B50 6 Existed Is the inspection result normal?
YES: INSPECTION END
NO: Repair the ADAS control unit ground circuit.