Component Inspection
- CHECK THROTTLE CONTROL MOTOR
- Turn ignition switch OFF.
- Disconnect electric throttle control actuator harness connector.
- Check resistance between electric throttle control actuator terminals as per the following.RESISTANCE REFERENCE
Electric throttle control actuator Resistance (Ω) Bank Terminals 1 1 and 2 Approx. 1 - 15 [at 25°C (77°F)] 2 5 and 6 Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
- Replace malfunctioning electric throttle control actuator.
- Go to
"SPECIAL REPAIR REQUIREMENT ".
INSPECTION END