Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK ASCD STEERING SWITCH CIRCUIT
With CONSULT-III
- Turn ignition switch ON.
- Select "MAIN SW", "CANCEL SW", "RESUME/ACC SW" and "SET SW" in "DATA MONITOR" mode with CONSULT-III.
- Check each item indication under the following conditions.CONDITION REFERENCE
Monitor item Condition Indication MAIN SW MAIN switch Pressed ON Released OFF CANCEL SW CANCEL switch Pressed ON Released OFF RESUME/ACC SW RESUME/ACCELERATE switch Pressed ON Released OFF SET SW SET/COAST switch Pressed ON Released OFF
Without CONSULT-III
- Turn ignition switch ON.
- Check the voltage between ECM harness connector terminals as per the following.VOLTAGE REFERENCE
ECM Condition Voltage (V) Connector + - Terminal Terminal M107 101 (ASCD steering switch signal) 108 MAIN switch: Pressed Approx. 0 CANCEL switch: Pressed Approx. 1 SET/COAST switch: Pressed Approx. 2 RESUME/ACCELERATE switch: Pressed Approx. 3 All ASCD steering switches: Released Approx. 4 Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 3.
- CHECK ASCD STEERING SWITCH GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Disconnect combination switch harness connector.
- Check the continuity between combination switch and ECM harness connector.CONTINUITY REFERENCE
Combination switch ECM Continuity Terminal Connector Terminal 16 M107 108 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Combination switch (spiral cable)
- Harness for open and short between ECM and combination switch
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK ASCD STEERING SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between combination switch and ECM harness connector.CONTINUITY REFERENCE
Combination switch ECM Continuity Terminal Connector Terminal 13 M107 101 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 6.
- Check the continuity between combination switch and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Combination switch (spiral cable)
- Harness for open and short between ECM and combination switch
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK ASCD STEERING SWITCH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 8.
NO: Replace ASCD steering switch.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END