  1. INTERVIEW FOR MALFUNCTION 

    Interview the customer to obtain as much information as possible about the conditions and environment under which the malfunction occurred.

    : GO TO 2.

  2. SYMPTOM CHECK 
    1. Check the symptom based on the information obtained from the customer.
    2. Perform "All DTC Reading" with CONSULT.

      Is U1000 detected? 

      YES: Perform CAN communication trouble diagnosis.

      NO: GO TO 3.

  3. CHECK DRIVE MODE SELECT SWITCH AND METER INDICATION 

    Compare combination meter indication with drive mode select switch pointer position.

    Does switch position accord with meter indication? 

    YES: Perform trouble diagnosis of malfunctioning system (DTC confirmation).

    NO: GO TO 4.

  4. CHECK THE DRIVE MODE SELECT SWITCH CIRCUIT 

    Perform inspection of drive mode select switch circuit. Refer to "DIAGNOSIS PROCEDURE ".

    Is inspection result normal? 

    YES: GO TO 5.

    NO: Repair or replace malfunctioning parts.

  5. CHECK THE DATA MONITOR OF COMBINATION METER 

    Compare "DRIVE MODE STATS" indication on the combination meter data monitor with drive mode select switch pointer position.

    Does switch position accord with data monitor indication? 

    YES: GO TO 6.

    NO: Perform trouble diagnosis of A/C auto amp. Refer to "CONSULT FUNCTION ".

  6. CHECK THE DATA MONITOR OF COMBINATION METER 

    Compare "DRIVE MODE STATS" indication on the combination meter data monitor with combination meter indication.

    Does meter indication accord with data monitor indication? 

    YES: GO TO  2.

    NO: Perform trouble diagnosis of combination meter. Refer to "CONSULT FUNCTION ".