How To Set
With CONSULT-III
Perform "TEMP SET CORRECT" of HVAC work support item.
WORK SUPPORT ITEM
| Work support items | Display (°C) | Display (°F) |
|---|---|---|
| TEMP SET CORRECT | 3.0 | 6 |
| 2.5 | 5 | |
| 2.0 | 4 | |
| 1.5 | 3 | |
| 1.0 | 2 | |
| 0.5 | 1 | |
| 0 (initial status) | 0 (initial status) | |
| -0.5 | -1 | |
| -1.0 | -2 | |
| -1.5 | -3 | |
| -2.0 | -4 | |
| -2.5 | -5 | |
| -3.0 | -6 |
NOTE:
- When -3.0°C (-6°F) is corrected on the temperature setting set as 25.0°C (77°F) the temperature controlled by A/C auto amp. is 25.0°C (77°F) -3.0°C (-6°F) = 22.0°C (72°F) and the temperature becomes lower than the temperature setting.
- When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.