Diagnosis Procedure
- CHECK STARTING SYSTEM
Turn ignition switch to START position.
Does the engine turn over? Does the starter motor operate?
YES: GO TO 2.
NO: Check starting system. (Refer to "DIAGNOSIS AND REPAIR WORK FLOW ".)
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace ground connection.
- CHECK CAMSHAFT POSITION (CMP) SENSOR POWER SUPPLY CIRCUIT-I
- Disconnect CMP sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between CMP sensor harness connector and ground.
DTC CMP sensor Ground Voltage (V) Bank Connector Terminal P0340 1 F5 1 Ground Approx. 5 P0345 2 F18 1 Is the inspection result normal?
YES: GO TO 9.
NO-1: P0340: Repair open circuit, short to ground or short to power in harness or connectors.
NO-2: P0345: GO TO 4.
- CHECK CMP SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between CMP sensor harness connector and ECM harness connector.
CMP sensor ECM Continuity Bank Connector Terminal Connector Terminal 2 F18 1 F102 64 Existed Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace error-detected parts.
- CHECK CMP SENSOR POWER SUPPLY CIRCUIT-III
Check harness for short to power and short to ground, between the following terminals:
ECM Sensor Connector Terminal Name Connector Terminal F101 46 Crankshaft position (CKP) sensor F2 1 F102 64 CMP sensor (bank 2) F18 1 Exhaust valve timing (EVT) control position sensor (bank 2) F19 1 Battery current sensor E21 1 M107 103 Accelerator pedal position (APP) sensor E112 (Without ICC) 6 E116 (With ICC) 3 107 EVAP control system pressure sensor B252 3 111 Refrigerant pressure sensor E77 3 Is the inspection result normal?
YES: GO TO 6.
NO: Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the Following:
- CKP sensor (Refer to "COMPONENT INSPECTION ".)
- EVT control position sensor (bank 2) (Refer to "COMPONENT INSPECTION ".)
- Battery current sensor (Refer to "COMPONENT INSPECTION ".)
- EVAP control system pressure sensor (Refer to "COMPONENT INSPECTION ".)
- Refrigerant pressure sensor (Refer to
"DIAGNOSIS PROCEDURE
".)
Is the inspection result normal?
YES: GO TO 7.
NO: Replace malfunctioning component.
- CHECK APP SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 15.
NO: GO TO 8.
- REPLACE ACCELERATOR PEDAL ASSEMBLY
Replace accelerator pedal assembly. Refer to "MODELS WITHOUT DISTANCE CONTROL ASSIST SYSTEM: REMOVAL AND INSTALLATION " (without distance control assist) or "MODELS WITH DISTANCE CONTROL ASSIST SYSTEM: REMOVAL AND INSTALLATION " (without distance control assist).
: INSPECTION END
- CHECK CMP SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between CMP sensor harness connector and ECM harness connector.
DTC CMP sensor ECM Continuity Bank Connector Terminal Connector Terminal P0340 1 F5 2 F102 96 Existed P0345 2 F18 2 92 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 11.
NO: GO TO 10.
- DETECT MALFUNCTIONING PART
Check the Following:
- Harness connectors F106, F107
- Harness for open or short between CMP sensor and ECM
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK CMP SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between CMP sensor harness connector and ECM harness connector.
DTC CMP sensor ECM Continuity Bank Connector Terminal Connector Terminal P0340 1 F5 3 F102 59 Existed P0345 2 F18 3 63 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 13.
NO: GO TO 12.
- Check the continuity between CMP sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the Following:
- Harness connectors F106, F107
- Harness for open or short between CMP sensor and ECM
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK CMP SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 14.
NO: Replace malfunctioning camshaft position sensor. Refer to "EXPLODED VIEW ".
- CHECK CAMSHAFT (INT)
Check the Following:
- Accumulation of debris to the signal plate of camshaft rear end
- Chipping signal plate of camshaft rear end
Is the inspection result normal?
YES: GO TO 15.
NO: Remove debris and clean the signal plate of camshaft rear end or replace camshaft. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Perform "INTERMITTENT INCIDENT ".
: INSPECTION END