Physical Values
WARNING: This page is about a different car, the 2011 Infiniti EX35. However, it is still accessible from the selected car via links, so may be relevant.
TERMINALS REFERENCE
| Terminal No. | Wire color | Description | Condition | Voltage (V) (Approx) | |||
|---|---|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | ||||
| 1 | Ground | L/W | UART communication (RX) | Input | Ignition switch ON | ||
| 3 | - | R/Y | CAN-H | - | - | - | |
| 9 | Ground | W/G | Reclining sensor signal | Input | Seat reclining | Operate | |
| Stop | 0 or 5 | ||||||
| 10 | Ground | P/B | Lifting sensor (rear) signal | Input | Seat lifting (rear) | Operate | |
| Stop | 0 or 5 | ||||||
| 11 | Ground | BR | Sliding switch backward signal | Input | Sliding switch | Operate (backward) | 0 |
| Release | Battery voltage | ||||||
| 12 | Ground | SB | Reclining switch backward signal | Input | Reclining switch | Operate (backward) | 0 |
| Release | Battery voltage | ||||||
| 13 | Ground | LG/R | Lifting switch (front) down signal | Input | Lifting switch (front) | Operate (down) | 0 |
| Release | Battery voltage | ||||||
| 14 | Ground | G/B | Lifting switch (rear) down signal | Input | Lifting switch (rear) | Operate (down) | 0 |
| Release | Battery voltage | ||||||
| 16 | Ground | O | Sensor power supply | Output | - | 5 | |
| 17 | Ground | Y/R | UART communication (TX) | Output | Ignition switch ON | ||
| 19 | - | V | CAN-L | - | - | - | |
| 21 | Ground | L/Y | Detention switch | Input | A/T selector lever | P position | 0 |
| Except P position | |||||||
| 24 | Ground | R | Sliding sensor signal | Input | Seat sliding | Operate | |
| Stop | 0 or 5 | ||||||
| 25 | Ground | Y/B | Lifting sensor (front) signal | Input | Seat lifting (front) | Operate | |
| Stop | 0 or 5 | ||||||
| 26 | Ground | Y | Sliding switch forward signal | Input | Sliding switch | Operate (forward) | 0 |
| Release | Battery voltage | ||||||
| 27 | Ground | R/G | Reclining switch forward signal | Input | Reclining switch | Operate (forward) | 0 |
| Release | Battery voltage | ||||||
| 28 | Ground | W/B | Lifting switch (front) up signal | Input | Seat lifting switch (front) | Operate (up) | 0 |
| Release | Battery voltage | ||||||
| 29 | Ground | P/L | Lifting switch (rear) up signal | Input | Seat lifting switch (rear) | Operate (up) | 0 |
| Release | Battery voltage | ||||||
| 31 | Ground | GR | Sensor ground | - | - | 0 | |
| 32 | Ground | B/W | Ground (signal) | - | - | 0 | |
| 33 | Ground | R | Power source (C/B) | Input | - | Battery voltage | |
| 35 | Ground | W/R | Sliding motor forward output signal | Output | Seat sliding | Operate (forward) | Battery voltage |
| Release | 0 | ||||||
| 36 | Ground | G/Y | Reclining motor forward output signal | Output | Seat reclining | Operate (forward) | Battery voltage |
| Release | 0 | ||||||
| 37 | Ground | G/W | Lifting motor (front) down output signal | Output | Seat lifting (front) | Operate (down) | Battery voltage |
| Stop | 0 | ||||||
| 38 | Ground | L/Y | Lifting motor (rear) up output signal | Output | Seat lifting (rear) | Operate (up) | Battery voltage |
| Stop | 0 | ||||||
| 39 | Ground | R/B | Lifting motor (rear) down output signal | Output | Seat lifting (rear) | Operate (down) | Battery voltage |
| Stop | 0 | ||||||
| 40 | Ground | R/W | Power source (Fuse) | Input | - | Battery voltage | |
| 42 | Ground | W/B | Sliding motor backward output signal | Output | Seat sliding | Operate (backward) | Battery voltage |
| Stop | 0 | ||||||
| 44 | Ground | P | Reclining motor backward output signal | Output | Seat reclining | Operate (backward) | Battery voltage |
| Stop | 0 | ||||||
| 45 | Ground | L/R | Lifting motor (front) up output signal | Output | Seat lifting (front) | Operate (up) | Battery voltage |
| Stop | 0 | ||||||
| 48 | Ground | B | Ground (power) | - | - | 0 | |