Work Procedure
The purpose of the operational check is to check that the individual system operates normally.
- CHECK MEMORY FUNCTION
- Set temperature to 32.0°C (90°F) by operating the temperature control switch.
- Press OFF switch.
- Turn ignition switch OFF.
- Turn ignition switch ON.
- Press AUTO switch.
- Check that set temperature is maintained.
Is the inspection result normal?
YES: GO TO 2.
NO: GO TO 10.
- CHECK AIR FLOW
- Operate fan control dial.
- Check that air flow changes. Check operation for all fan speeds.
Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 10.
- CHECK AIR OUTLET
- Operate fan control dial to set the fan speed to maximum speed.
- Operate MODE switch and DEF switch.
- Check that air outlets change according to each indicated air outlet by placing a hand in front of the air outlets. Refer to
"VENTILATION SYSTEM : SYSTEM DESCRIPTION
".
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 10.
- CHECK AIR INLET
- Press intake switch to set the air inlet to recirculation. [Intake switch indicator (side) turns ON.]
- Listen to intake sound and confirm air inlets change.
- Press intake switch again to set the air inlet to fresh air intake. [Intake switch indicator (side) turns OFF and (side) turns ON.]
- Listen to intake sound and confirm air inlets change.
Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 10.
- CHECK COMPRESSOR
- Press A/C switch. The A/C switch indicator is turns ON.
- Check visually and by sound that the compressor operates.
- Press A/C switch again The A/C switch indicator is turns OFF.
- Check that compressor stops.
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 10.
- CHECK DISCHARGE AIR TEMPERATURE
- Operate temperature control switch.
- Check that discharge air temperature changes.
Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 10.
- CHECK TEMPERATURE DECREASE
- Operate compressor.
- Operate temperature control dial and lower the set temperature to 18.0°C (60°F).
- Check that cool air blows from the air outlets.
Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 10.
- CHECK TEMPERATURE INCREASE
- Operate temperature control switch and raise the set temperature to 32.0°C (90°F).
- Check that warm air blows from the air outlets.
Is the inspection result normal?
YES: GO TO 9.
NO: GO TO 10.
- CHECK AUTO MODE
- Press AUTO switch to confirm that "AUTO" is indicated on the display.
- Operate temperature control switch to check that air outlet or air flow changes (the air outlet or air flow varies depending on the ambient temperature, in-vehicle temperature, set temperature, and etc.).
Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 10.
- CHECK SELF-DIAGNOSIS WITH CONSULT
- Perform self-diagnosis with CONSULT.
- Check that any DTC is detected.
Is any DTC detected?
YES: Refer to "DTC INDEX " and perform the appropriate diagnosis.
NO: Refer to "SYMPTOM TABLE " and perform the appropriate diagnosis.