Data Monitor

WARNING: This page is about a different car, the 2011 Nissan Leaf. However, it is still accessible from the selected car via links, so may be relevant.

Communication signals of A/C auto amp. can be checked.

Display Item List

DATA MONITOR ITEMS DESCRIPTION CHART

Monitor item [STATUS or UNIT] DESCRIPTION
Ambient sensor [°C/°F] Value of ambient sensor detection value (voltage), converted to ambient temperature
In-vehicle sensor [°C/°F] Value of in-vehicle sensor detection value (voltage), converted to interior temperature
Intake sensor [°C/°F] Value of intake sensor detection value (voltage), converted to intake temperature
Sunload sensor [W/m2 ] Value of sunload sensor detection value (voltage), converted to sunload
Ambient sensor value [°C/°F] Value of ambient temperature calculated by A/C auto amp.
In-vehicle sensor value [°C/°F] Value of interior temperature calculated by A/C auto amp.
Intake sensor value [°C/°F] Value of intake temperature calculated by A/C auto amp.
Sunload sensor value [W/m2 ] Value of sunload calculated by A/C auto amp.
Compressor request [On/Off] A/C ON signal ON/OFF status
Blower fan request [On/Off] Blower fan ON signal ON/OFF status
Blower fan duty(1) Target value of voltage (applied voltage) applied to Blower fan motor by A/C auto amp.
XM Target discharge air temperature judged by A/C auto amp. according to the temperature setting and the value from each sensor
COMPR RPM [RPM] Rotation speed of electric compressor
COMPR INPUT POWER SIG [W] Power consumption value of electric compressor
COMPR INPUT CRNT CHARGE [A] Input current value of electric compressor
COMPR IPM TEMP SIG [°C/°F] Detection value of IPM temperature sensor inside electric compressor
COMPR INPUT VOLT SIG [V] Input voltage value of electric compressor
COMPR DISCHR TMP OVRHEAT [OK/NG] If the compressor discharge refrigerant temperature (estimated value) exceeds 130°C, status is NG.
COMPR IPM OVERHEAT [OK/NG]
  • If the IPM temperature exceeds 125°C within 1 minute after start, status is NG.
  • If the IPM temperature exceeds 88°C 1 minute or more after start, status is NG.
COMPR VOLT SATURATION [OK/NG] If the inverter output voltage increases to 140% or more, status is NG.
COMPR OVER CURRENT [OK/NG]
  • Start failed 3 times because current of 35.1 A or more flowed within 90 seconds after start.
  • Current of 35.1 A or more flows when compressor is stopped.
COMPR OVER LOADED [OK/NG] If the input current of the electric compressor increases to 13.5 A or more, status is NG.
COMPR LOW VOLT ERROR [OK/NG] If the input voltage of the electric compressor lowers less than 230 V, status is NG.
COMPR HIGH VOLT ERROR [OK/NG] If the input voltage of the electric compressor exceeds 420 V, status is NG.
COMM ERROR HVAC→-COMPR [OK/NG] If the electric compressor recognizes an UART communication error, status is NG.
COMPR IPM TEMP SEN ERROR [OK/NG] If an open circuit or short circuit is recognized for the IPM temperature sensor, status is NG.
COMPR SHUNT SIG ERROR [OK/NG] If the shunt signal in the electric compressor is judged abnormal, status is NG.
COMPR ROM,RAM,AD ERROR [OK/NG] If any data error is detected in the ROM or RAM area of the electric compressor, status is NG.
COMPR DISCHRG TEMP LIMIT [OK/NG] If the discharge temperature estimated value exceeds 110°C, status is NG.
COMPR IPM TEMP LIMIT [OK/NG] If the IPM temperature exceeds 83°C, status is NG.
COMPR LOW SPEED OVR LOAD [OK/NG] If the compressor cannot rotate at the specified speed, status is NG.
COMM ERROR COMP→HVAC [OK/NG] If the A/C auto amp. recognizes an UART communication error, status is NG.
PTC HEATER REQUEST [%] Operating rate sent to the PTC element heater by the A/C auto amp.
PTC HEATER CIRCUIT [OK/NG] If the diagnosis value for the control element inside PTC element heater exceeds the specified value, status is NG.
PTC OVERHEAT PROTECTION [OK/NG] If the board temperature inside PTC element heater exceeds the control value, status is NG.
PTC HEATER VOLTAGE [OK/NG] If the voltage applied to PTC element heater exceeds the specified value, status is NG.
PTC HEATER CIRCUIT 1 [OK/NG] If the diagnosis value for the control element 1 inside PTC element heater exceeds the specified value, status is NG.
PTC HEATER CIRCUIT 2 [OK/NG] If the diagnosis value for the control element 2 inside PTC element heater exceeds the specified value, status is NG.
PTC HEATER CIRCUIT 3 [OK/NG] If the diagnosis value for the control element 3 inside PTC element heater exceeds the specified value, status is NG.
PTC HEATER CIRCUIT 4 [OK/NG] If the diagnosis value for the control element 4 inside PTC element heater exceeds the specified value, status is NG if so designed.
PTC LIN COMMUNICATION [OK/NG] If the PTC element heater recognizes an error in the LIN communication from the A/C auto amp., status is NG.
PTC COMMUNICATION [OK/NG] If the A/C auto amp. recognizes an error in the LIN communication from the PTC element heater, status is NG.
PTC INTERLOCK [OK/NG] If an error is detected in the connection check for the PTC element heater high-voltage connector, status is NG.
COMM ERROR PTC→HVAC [OK/NG] If the A/C auto amp. recognizes an error in the LIN communication from the PTC element heater, status is NG.
COMP USE PERMIT POWER [W] Power available to electric compressor calculated by A/C auto amp.
REFRIGERANT PRE SEN [Mpa] Refrigerant pressure sensor detection value sent from VCM
FORCED OFF SIG [ON/OFF] State of input signal to A/C auto amp.
FORCED INTAKE REC SIG [ON/OFF] State of input signal to A/C auto amp.
PRE-CLIMATE SIGNAL [ON/OFF] State of input signal to A/C auto amp.
HV SPLY/BLOCK CMPL FLAG [ON/OFF] State of input signal to A/C auto amp.
COMM ERROR VCM→HVAC [OK/NG] If the A/C auto amplifier recognizes an error in the CAN communication from VCM, status is NG.
PTC CONSUMPTION VOLT [W] Power available to PTC element heater calculated by A/C auto amp.
WATER TEMPSENSOR [°C/°F] Value of heater fluid temperature sensor detection value (voltage), converted to temperature
PUMP RPM (DIRECTION) [RPM] Value sent to heater pump by A/C auto amp.
PUMP RPM (EFFECTIVE) [RPM] Actual rotation speed of heater pump
PUMP CANNOT READ INPUT SIG [ON/OFF] If the heater pump cannot read out any PWM signal output from the A/C auto amp., status is ON.
H/P OPERATION LIMIT [ON/OFF] If a pump malfunction is detected, the status is ON.
HEATER PUMP VOLTAGE [OK/NG] If the heater pump input voltage is less than 8 V or is 16 V or more, status is NG.
HEATER PUMP FAULT [OK/NG] If a pump malfunction is judged, status is NG.
COMM ERROR H/P→HVAC [OK/NG] If the DUTY signal from heater pump is not normal, status is NG.
(1) "DUTY" is displayed however the voltage is indicated. Or value is not displayed, but unit is (V).