Physical Values
WARNING: This page is about a different car, the 2011 Nissan Leaf. However, it is still accessible from the selected car via links, so may be relevant.
ELECTRIC SHIFT CONTROL MODULE TERMINALS REFERENCE CHART
| Terminal (Wire color) | Item | Condition | Value (Approx.) | |||
|---|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | |||
| 1 (L) | Ground | MOTOR COIL A U-PHASE | Output | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 2 (W) | Ground | MOTOR COIL A V-PHASE | Output | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 3 (B) | Ground | GND | - | Always | 0 V | |
| 4 (B) | Ground | GND | - | Always | 0 V | |
| 5 (V) | Ground | MOTOR COIL A WPHASE | Output | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 6 (B) | Ground | GND (MOTOR) | - | Always | 0 V | |
| 7 (W) | Ground | MAIN POWER SUPPLY 1 | Input | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 8 (R) | Ground | BACK UP POWER SUPPLY | Input | Always | 9 - 16 V | |
| 9 (BR) | Ground | POWER SW 1 | Input | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 10 (Y) | Ground | ANGLE SENSOR 1 POWER SUPPLY | - | Power switch ON | 5 V | |
| 11 (L) | Ground | ANGLE SENSOR 1 SIGNAL | Input | READY | Selector lever is P position (Manual plate: P position) | 1.42 - 2.20 V |
| Other than the above (Manual plate: Not P position) | 2.85 - 3.56 V | |||||
| 12 (W) | Ground | P POSITION SIGNAL | Output | READY | Selector lever is P position | 0 V |
| Other than the above | 9 - 16 V | |||||
| 13 (R) | Ground | P/N POSITION SIGNAL | Output | READY | Selector lever is P and N positions | 9 - 16 V |
| Other than the above | 0 V | |||||
| 14 (P) | Ground | STOP LAMP SWITCH | Input | Power switch ON | Brake pedal is depressed | 9 - 16 V |
| Brake pedal is released | 0 V | |||||
| 15 (LG) | Ground | ENCODER SIGNAL B | Input | Parking actuator is operated | ||
| 16 (R) | Ground | ENCODER POWER SUPPLY | - | Power switch ON | 5 V | |
| 17 (V) | Ground | ELECTRIC SHIFT POWER SUPPLY RELAY | Output | Power switch ON | 0 V | |
| Power switch OFF | 9 - 16 V | |||||
| 18 (SB) | Ground | PARKING ACTUATOR RELAY A | - | Power switch ON | 0 V | |
| Power switch OFF | 9 - 16 V | |||||
| 19 (P) | Ground | ELECTRIC SHIFT SENSOR POWER SUPPLY 1 | - | Power switch ON | 5 V | |
| 20 (LG) | Ground | WAKE UP SIGNAL | Input | Power switch ON | 9 - 16 V | |
| 21 (GR) | Ground | ANGLE SENSOR 1 GND | - | Always | 0 V | |
| 22 (L) | Ground | N POSITION OUTPUT (SELECTOR INDICATOR) | Output | READY | Selector lever is N position | 1 V or less |
| Other than the above | 9 - 16 V | |||||
| 23 (G) | Ground | ENCODER GND | - | Always | 0 V | |
| 24 (W) | Ground | ENCODER SIGNAL A | Input | Parking actuator is operated | ||
| 25 (B) | Ground | GND (MOTOR) | - | Always | 0 V | |
| 26 (R) | Ground | D POSITION OUTPUT (SELECTOR INDICATOR) | Output | READY | Selector lever is D position | 1 V or less |
| Other than the above | 9 - 16 V | |||||
| 27 (BR) | Ground | MOTOR COIL B U-PHASE | Output | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 28 (GR) | Ground | MOTOR COIL B V-PHASE | Output | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 29 (R) | Ground | MOTOR COIL B W-PHASE | Output | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 30 (Y) | Ground | R POSITION OUTPUT (SELECTOR INDICATOR) | Output | READY | Selector lever is R position | 1 V or less |
| Other than the above | 9 - 16 V | |||||
| 31 (L) | Ground | EV SYSTEM CAN-H | Input/Output | - | - | |
| 32 (G) | Ground | EV SYSTEM CAN-L | Input/Output | - | - | |
| 33 (GR) | Ground | PARKING ACTUATOR RELAY B | - | Power switch ON | 0 V | |
| Power switch OFF | 9 - 16 V | |||||
| 34 (B) | Ground | ELECTRIC SHIFT SENSOR NO. 1 | Input | READY | Selector lever is held in R position | 0 V |
| Other than the above | 5 V | |||||
| 35 (L) | Ground | ELECTRIC SHIFT SENSOR NO. 2 | Input | READY | Selector lever is held in R and N positions | 0 V |
| Other than the above | 5 V | |||||
| 36 (R) | Ground | ELECTRIC SHIFT SENSOR NO. 3 | Input | READY | Selector lever is held in H (Home) and N positions | 0 V |
| Other than the above | 5 V | |||||
| 37 (Y) | Ground | ELECTRIC SHIFT SENSOR NO. 4 | Input | READY | Selector lever is held in N and D position | 0 V |
| Other than the above | 5 V | |||||
| 38 (B) | Ground | P POSITION OUTPUT (SELECTOR INDICATOR) | Output | READY | Selector lever is P position | 1 V or less |
| Other than the above | 9 - 16 V | |||||
| 39 (LG) | Ground | ANGLE SENSOR 2 POWER SUPPLY | - | Power switch ON | 5 V | |
| 40 (P) | Ground | ANGLE SENSOR 2 SIGNAL | Input | READY | Selector lever is P position (Manual plate: P position) | 1.42 - 2.20 V |
| Other than the above (Manual plate: Not P position) | 2.85 - 3.56 V | |||||
| 41 (BR) | Ground | ELECTRIC SHIFT SENSOR GND 1 | - | Always | 0 V | |
| 42 (G) | Ground | POWER SW 2 | Input | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 43 (W) | Ground | MAIN POWER SUPPLY 2 | Input | Power switch ON | 9 - 16 V | |
| Power switch OFF | 0 V | |||||
| 44 (W) | Ground | ELECTRIC SHIFT SENSOR NO. 5 | Input | READY | Selector lever is held in D position | 0 V |
| Other than the above | 5 V | |||||
| 45 (G) | Ground | ELECTRIC SHIFT SENSOR NO. 6 | Input | READY | Selector lever in H (Home) position | 0 V |
| Other than the above | 5 V | |||||
| 46 (R) | Ground | P POSITION SWITCH NO. 7 | Input | READY | P position switch is pushed | 5 V |
| Other than the above | 0 V | |||||
| 47 (B) | Ground | P POSITION SWITCH NO. 8 | Input | READY | P position switch is pushed | 0 V |
| Other than the above | 5 V | |||||
| 48 (SB) | Ground | ELECTRIC SHIFT SENSOR POWER SUPPLY 2 | - | Power switch ON | 5 V | |
| 49 (G) | Ground | ANGLE SENSOR 2 GND | - | Always | 0 V | |
| 50 (LG) | Ground | ELECTRIC SHIFT SENSOR GND 2 | - | Always | 0 V | |