LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2012 >> G25 Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 15 (Automatic Transmission) >> Electric Shift >> Ecu Diagnosis Information >> Electric Shift Control Module >> Reference Value >> Physical Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Physical Values

WARNING: This page is about a different car, the 2011 Nissan Leaf. However, it is still accessible from the selected car via links, so may be relevant.
ELECTRIC SHIFT CONTROL MODULE TERMINALS REFERENCE CHART

Terminal (Wire color) Item Condition Value (Approx.)
+ - Signal name Input/Output
1 (L) Ground MOTOR COIL A U-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
2 (W) Ground MOTOR COIL A V-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
3 (B) Ground GND - Always 0 V
4 (B) Ground GND - Always 0 V
5 (V) Ground MOTOR COIL A WPHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
6 (B) Ground GND (MOTOR) - Always 0 V
7 (W) Ground MAIN POWER SUPPLY 1 Input Power switch ON   9 - 16 V
Power switch OFF   0 V
8 (R) Ground BACK UP POWER SUPPLY Input Always 9 - 16 V
9 (BR) Ground POWER SW 1 Input Power switch ON   9 - 16 V
Power switch OFF   0 V
10 (Y) Ground ANGLE SENSOR 1 POWER SUPPLY - Power switch ON   5 V
11 (L) Ground ANGLE SENSOR 1 SIGNAL Input READY Selector lever is P position (Manual plate: P position) 1.42 - 2.20 V
Other than the above (Manual plate: Not P position) 2.85 - 3.56 V
12 (W) Ground P POSITION SIGNAL Output READY Selector lever is P position 0 V
Other than the above 9 - 16 V
13 (R) Ground P/N POSITION SIGNAL Output READY Selector lever is P and N positions 9 - 16 V
Other than the above 0 V
14 (P) Ground STOP LAMP SWITCH Input Power switch ON Brake pedal is depressed 9 - 16 V
Brake pedal is released 0 V
15 (LG) Ground ENCODER SIGNAL B Input Parking actuator is operated  
G07084439Courtesy of NISSAN MOTOR CO., U.S.A.
16 (R) Ground ENCODER POWER SUPPLY - Power switch ON   5 V
17 (V) Ground ELECTRIC SHIFT POWER SUPPLY RELAY Output Power switch ON   0 V
Power switch OFF   9 - 16 V
18 (SB) Ground PARKING ACTUATOR RELAY A - Power switch ON   0 V
Power switch OFF   9 - 16 V
19 (P) Ground ELECTRIC SHIFT SENSOR POWER SUPPLY 1 - Power switch ON   5 V
20 (LG) Ground WAKE UP SIGNAL Input Power switch ON   9 - 16 V
21 (GR) Ground ANGLE SENSOR 1 GND - Always 0 V
22 (L) Ground N POSITION OUTPUT (SELECTOR INDICATOR) Output READY Selector lever is N position 1 V or less
Other than the above 9 - 16 V
23 (G) Ground ENCODER GND - Always 0 V
24 (W) Ground ENCODER SIGNAL A Input Parking actuator is operated
G07084440Courtesy of NISSAN MOTOR CO., U.S.A.
25 (B) Ground GND (MOTOR) - Always 0 V
26 (R) Ground D POSITION OUTPUT (SELECTOR INDICATOR) Output READY Selector lever is D position 1 V or less
Other than the above 9 - 16 V
27 (BR) Ground MOTOR COIL B U-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
28 (GR) Ground MOTOR COIL B V-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
29 (R) Ground MOTOR COIL B W-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
30 (Y) Ground R POSITION OUTPUT (SELECTOR INDICATOR) Output READY Selector lever is R position 1 V or less
Other than the above 9 - 16 V
31 (L) Ground EV SYSTEM CAN-H Input/Output - -
32 (G) Ground EV SYSTEM CAN-L Input/Output - -
33 (GR) Ground PARKING ACTUATOR RELAY B - Power switch ON   0 V
Power switch OFF   9 - 16 V
34 (B) Ground ELECTRIC SHIFT SENSOR NO. 1 Input READY Selector lever is held in R position 0 V
Other than the above 5 V
35 (L) Ground ELECTRIC SHIFT SENSOR NO. 2 Input READY Selector lever is held in R and N positions 0 V
Other than the above 5 V
36 (R) Ground ELECTRIC SHIFT SENSOR NO. 3 Input READY Selector lever is held in H (Home) and N positions 0 V
Other than the above 5 V
37 (Y) Ground ELECTRIC SHIFT SENSOR NO. 4 Input READY Selector lever is held in N and D position 0 V
Other than the above 5 V
38 (B) Ground P POSITION OUTPUT (SELECTOR INDICATOR) Output READY Selector lever is P position 1 V or less
Other than the above 9 - 16 V
39 (LG) Ground ANGLE SENSOR 2 POWER SUPPLY - Power switch ON 5 V
40 (P) Ground ANGLE SENSOR 2 SIGNAL Input READY Selector lever is P position (Manual plate: P position) 1.42 - 2.20 V
Other than the above (Manual plate: Not P position) 2.85 - 3.56 V
41 (BR) Ground ELECTRIC SHIFT SENSOR GND 1 - Always 0 V
42 (G) Ground POWER SW 2 Input Power switch ON   9 - 16 V
Power switch OFF   0 V
43 (W) Ground MAIN POWER SUPPLY 2 Input Power switch ON   9 - 16 V
Power switch OFF   0 V
44 (W) Ground ELECTRIC SHIFT SENSOR NO. 5 Input READY Selector lever is held in D position 0 V
Other than the above 5 V
45 (G) Ground ELECTRIC SHIFT SENSOR NO. 6 Input READY Selector lever in H (Home) position 0 V
Other than the above 5 V
46 (R) Ground P POSITION SWITCH NO. 7 Input READY P position switch is pushed 5 V
Other than the above 0 V
47 (B) Ground P POSITION SWITCH NO. 8 Input READY P position switch is pushed 0 V
Other than the above 5 V
48 (SB) Ground ELECTRIC SHIFT SENSOR POWER SUPPLY 2 - Power switch ON   5 V
49 (G) Ground ANGLE SENSOR 2 GND - Always 0 V
50 (LG) Ground ELECTRIC SHIFT SENSOR GND 2 - Always 0 V