LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2012 >> G25 x >> Repair and Diagnosis >> External Pages >> Different car >> Section 6 (EV Control System) >> System Description >> System >> Air Conditioner Control >> AIR CONDITIONER CONTROL: System Description >> Control Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Control Description

WARNING: This page is about a different car, the 2011 Nissan Leaf. However, it is still accessible from the selected car via links, so may be relevant.

Air Conditioner Control During Charging

VCM allows the air conditioner to be used during charging. In this case, the air conditioner stops when charging is completed.

NOTE: If the Li-ion battery available charge gauge level is lower than Level 2, the A/C does not operate during battery charge.

Timer Air Conditioning Control

When all of the following conditions are satisfied, VCM activates the timer air conditioner so that the room temperature reaches 25 °C (77°F) before the scheduled departure time.

Regarding the timer air conditioner operation time, VCM starts the EV system 2 hours prior to the scheduled department time, and the A/C auto amp. determines the necessary operating time in the range of 0 to 2 hours based on the outside air temperature and the temperature in the cabin and sends this information to VCM. VCM back calculates the operation required time from the scheduled department time to determine the timer air conditioner start time.

Furthermore, when the timer charge function and the timer air conditioner function are in operation at the same time due to an overlap of the timer setting, either function can be set to be preferentially provided with electric power.

NOTE:
  • When turning on the power during timer air conditioning, switch to normal air conditioning control.
  • When timer charge and the timer air conditioner operate simultaneously, VCM distributes power to the air conditioner system and the charge system according to the priority set on the navigation screen.

Remote Air Conditioning Control

When VCM receives the remote air conditioning request signal from the TCU, the air conditioning is operated.

Remote air-conditioner operates as follows.

REMOTE AIR-CONDITIONER OPERATING TIME REFERENCE CHART

Condition Operating time (min)
Charge connector is not connected. 15
When connecting EVSE (with AC input) 15 - 120
During Quick charge 15 - 120
NOTE: When the power is turned on during remote air conditioning, the remote air conditioning is ended.