Values On The Diagnosis Tool
WARNING: This page is about a different car, the 2011 Nissan 370Z. However, it is still accessible from the selected car via links, so may be relevant.
CONSULT-III MONITOR ITEM
MONITOR ITEM DESCRIPTION
| Monitor Item | Condition | Status/Value | |
|---|---|---|---|
| ROOF LATCHED RH | State of roof lock is in roof latch RH | Lock position | ON |
| Other than above | OFF | ||
| Roof striker sensor RH circuit is open or short | NG | ||
| ROOF LATCHED LH | State of roof lock is in roof latch LH | Lock position | ON |
| Other than above | OFF | ||
| Roof striker sensor LH circuit is open or short | NG | ||
| F/CENTER LOCK | State of roof latch cylinder | Lock | ON |
| Other than above | OFF | ||
| Roof latch lock sensor circuit is open or short | NG | ||
| R/RAIL RAISED LH | State of roof drive cylinder LH | Soft top is close | ON |
| Other than above | OFF | ||
| Roof status sensor LH circuit is open or short | NG | ||
| R/RAIL RAISED RH | State of roof drive cylinder RH | Soft top is close | ON |
| Other than above | OFF | ||
| Roof status sensor RH circuit is open or short | NG | ||
| R/RAIL LOWERED | State of roof drive cylinder LH | Soft top is open | ON |
| Other than above | OFF | ||
| Roof status sensor LH circuit is open or short | NG | ||
| 5TH BOW LOWERED | State of 5th bow drive cylinder LH | 5th bow is close | ON |
| Other than above | OFF | ||
| 5th bow status sensor LH circuit is open or short | NG | ||
| 5TH BOW RAISED | State of 5th bow drive cylinder RH | 5th bow is open | ON |
| Other than above | OFF | ||
| 5th bow status sensor RH circuit is open or short | NG | ||
| S/LID OPEN LH | State of storage lid drive cylinder LH | Storage lid is open | ON |
| Other than above | OFF | ||
| Storage lid status sensor LH circuit is open or short | NG | ||
| S/LID OPEN RH | State of storage lid drive cylinder RH | Storage lid is open | ON |
| Other than above | OFF | ||
| Storage lid status sensor RH circuit is open or short | NG | ||
| S/LID CLOSE RH | State of storage lid drive cylinder RH | Storage lid is close | ON |
| Other than above | OFF | ||
| Storage lid status sensor RH circuit is open or short | NG | ||
| 5TH BOW LATCH OP | State of 5th bow latch cylinder | Unlock | ON |
| Other than above | OFF | ||
| 5th bow latch open sensor circuit is open or short | NG | ||
| SWITCH VALVE 1 | Operation of switching valve 1 | Operate | ON |
| Stop | OFF | ||
| Switching valve 1 circuit is short | NG | ||
| SWITCH VALVE 2 | Operation of switching valve 2 | Operate | ON |
| Stop | OFF | ||
| Switching valve 2 circuit is short | NG | ||
| SWITCH VALVE 3 | Operation of switching valve 3 | Operate | ON |
| Stop | OFF | ||
| Switching valve 3 circuit is short | NG | ||
| SWITCH VALVE 4 | Operation of switching valve 4 | Operate | ON |
| Stop | OFF | ||
| Switching valve 4 circuit is short | NG | ||
| SWITCH VALVE 5 | Operation of switching valve 5 | Operate | ON |
| Stop | OFF | ||
| Switching valve 5 circuit is short | NG | ||
| PUMP OUT (RH) | Operation of hydraulic pump motor | Turning clockwise | ON |
| Other than above | OFF | ||
| Hydraulic pump motor (RH) circuit is short | NG | ||
| PUMP OUT (LH) | Operation of hydraulic pump motor | Turning counterclockwise | ON |
| Other than above | OFF | ||
| Hydraulic pump motor (LH) circuit is short | NG | ||
| 5TH BOW LATCH CL | State of 5th bow latch cylinder | Lock | ON |
| Other than above | OFF | ||
| 5th bow latch close sensor circuit is open or short | NG | ||
| ROOF SW (OPEN) | State of roof open/close switch | OPEN operation is in operation | ON |
| Other than above | OFF | ||
| ROOF SW (CLOSE) | State of roof open/close switch | CLOSE operation is in operation | ON |
| Other than above | OFF | ||
| SHIFT R SIGNAL | Shift position | R position | ON |
| Other than R position | OFF | ||
| TRUNK OPEN OUT | Operation of trunk lid opener actuator | OPEN operation is in operation | ON |
| Other than above | OFF | ||
| THER PROTEC PUMP | Thermo protection hydraulic pump | In non-operation | OK |
| In operation | NG | ||
| THER PROTEC RCU | Thermo protection soft top control unit | In non-operation | OK |
| In operation | NG | ||
| PWR COND RCU | Power supply voltage state of soft top control unit | Normal | OK |
| Malfunction | NG | ||
| PWR COND P/W | Power supply voltage state of power window | Normal | OK |
| Malfunction | NG | ||
| LOCAL COMM 1 | State of local communication 1 | Normal | OK |
| It is in sleep mode | SLEEP | ||
| Communication error | NG | ||
| LOCAL COMM 2 | State of local communication 2 | Normal | OK |
| It is in sleep mode | SLEEP | ||
| Communication error | NG | ||
| REAR DEF OUT | Operation of rear window defogger | Roof position is full close | OK |
| Other than above | NG | ||
| 5BOW STRIK LATCH | State of 5th bow latch | 5th bow striker is in 5th bow latch | ON |
| Other than above | OFF | ||
| 5th bow striker sensor circuit is open or short | NG | ||
| P/W OP REQ SW SIG | State of request switch signal | OPEN operation is in operation | ON |
| Stop | OFF | ||
| PROHIBIT P/W UP | Prohibit of power window up | In operation | ON |
| In non-operation | OFF | ||
| IGN ON SIG(BCM) | Power position signal | Ignition switch ON | ON |
| Other than above | OFF | ||
| RF OP REQ SW SIG | State of request switch signal | OPEN operation is in operation | ON |
| Stop | OFF | ||