Home >> Infiniti >> 2012 >> G37 IPL, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (HVAC Control System (Sedan)) >> Basic Inspection >> Inspection And Adjustment >> With PLASMACLUSTER System >> WITH PLASMACLUSTER SYSTEM: Exhaust Gas/Outside Odor Detecting Sensor Sensitivity Adjustment Function >> Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

WITH PLASMACLUSTER SYSTEM: Exhaust Gas/Outside Odor Detecting Sensor Sensitivity Adjustment Function: Description

WARNING: This page is about a different variant/trim than selected.

According to customer's sense of smell, exhaust gas/outside odor detecting sensor sensitivity can be changed.

Operating procedures for this trimmer are as follows:

  1. Begin self-diagnosis STEP-5 mode. Refer to "WITH PLASMACLUSTER SYSTEM: Diagnosis Description ".
  2. Press fan (UP: +) switch two times to set system in auxiliary mode.
  3. Turn temperature control dial (driver side) as desired.
Display Setting
71 Less sensitive setting than display 72 setting (the change to REC is later than display 72 operation)
72 Less sensitive setting than normal setting (the change to REC is later than normal operation)
73 Normal (Initial setting)
74 More sensitive setting than normal setting (the change to REC is earlier than normal operation)
75 More sensitive setting than display 74 setting (the change to REC is earlier than display 74 operation)
NOTE: When battery cable is disconnected or battery voltage is below 10 V, exhaust gas/outside odor detecting sensor sensitivity adjustment function is canceled. Exhaust gas/outside odor detecting sensor sensitivity adjustment function set becomes that of initial condition.