Home >> Infiniti >> 2012 >> G37 IPL, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (HVAC Control System (Sedan)) >> Basic Inspection >> Inspection And Adjustment >> With PLASMACLUSTER System >> WITH PLASMACLUSTER SYSTEM: Foot Position Setting Trimmer >> Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

WITH PLASMACLUSTER SYSTEM: Foot Position Setting Trimmer: Description

WARNING: This page is about a different variant/trim than selected.

Wind distribution ratio in FOOT mode can be set.

Operating procedures for this trimmer are as per the following:

  1. Begin self-diagnosis STEP-5 mode. Refer to "WITHOUT PLASMACLUSTER SYSTEM: Diagnosis Description ".
  2. Press fan (UP: +) switch to set system in auxiliary mode.
  3. Press mode switch as desired.
DISCHARGE AIR FLOW - WITHOUT REAR VENTIRATION

Display Discharge air flow
Automatically controls the mode door Manually controls the mode door
VENT FOOT DEF VENT FOOT DEF
Front Rear Front Rear
G08458798Courtesy of NISSAN NORTH AMERICA, INC.
11% 39% 24% 26% 11% 39% 24% 26%
G08458799Courtesy of NISSAN NORTH AMERICA, INC.
11% 39% 24% 26% 15% 53% 32% -
G08458800Courtesy of NISSAN NORTH AMERICA, INC.
15% 53% 32% - 11% 39% 24% 26%
G08458801Courtesy of NISSAN NORTH AMERICA, INC.
15% 53% 32% - 15% 53% 32% -
DISCHARGE AIR FLOW - WITH REAR VENTIRATION

Display Discharge air flow
Automatically controls the mode door Manually controls the mode door
VENT FOOT DEF VENT FOOT DEF
Front Rear Front Rear Front Rear Front Rear
G08458802Courtesy of NISSAN NORTH AMERICA, INC.
10% 12% 33% 22% 23% 10% 12% 33% 22% 23%
G08458803Courtesy of NISSAN NORTH AMERICA, INC.
10% 12% 33% 22% 23% 13% 16% 43% 28% -
G08458804Courtesy of NISSAN NORTH AMERICA, INC.
13% 16% 43% 28% - 10% 12% 33% 22% 23%
G08458805Courtesy of NISSAN NORTH AMERICA, INC.
13% 16% 43% 28% - 13% 16% 43% 28% -
NOTE: When battery cable is disconnected or battery voltage is below 10 V, trimmer operation is canceled. Air distribution ratio set becomes that of initial condition.