Inspection procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK OPERATION
- Set temperature control dial to 32°C (90°F).
- Press OFF switch.
- Turn ignition switch OFF.
- Turn ignition switch ON.
- Press AUTO switch.
- Check that the set temperature is maintained.
Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- CHECK POWER SUPPLY AND GROUND CIRCUIT OF UNIFIED METER AND A/C AMP
Check power supply and ground circuit of unified meter and A/C amp. Refer to "UNIFIED METER AND A/C AMP.: Diagnosis Procedure ".
Is the inspection result normal?
YES: Replace unified meter and A/C amp.
NO: Repair or replace malfunctioning part.