Air Mix Door Control Specification
WARNING: This page is about a different variant/trim than selected.
When ignition switch is ON, unified meter and A/C amp. continuously and automatically controls temperatures regardless of air conditioning operational condition. When setting a target temperature with temperature control dial, unified meter and A/C amp. corrects the set temperature and decides a target air mix door opening angle. Unified meter and A/C amp. controls air mix door according to the target air mix door opening angle and current air mix door opening angle for keeping an optimum air mix door opening angle. When a temperature is set at 18°C (64°F), air mix door is fixed at full cold, and when a temperature is set at 32°C (90°F), it is set at full hot.