Consult Data Monitor Reference Values
| Monitor item | Condition | Value/Status | |||
|---|---|---|---|---|---|
| COMP REQ SIG | Engine: Run at idle after warming up | "A/C": ON (Compressor operation status) |
On | ||
| "A/C": OFF | Off | ||||
| FAN REQ SIG | Engine: Run at idle after warming up | Blower motor: ON | On | ||
| Blower motor: OFF | Off | ||||
| DR TARGET A/TEMP | Ignition switch ON | Values depending on target air flow temperature (driver side) | |||
| PA TARGET A/TEMP | Ignition switch ON | Values depending on target air flow temperature (passenger side) | |||
| AMB TEMP SEN | Ignition switch ON | Equivalent to ambient temperature | |||
| IN-VEH TEMP | Ignition switch ON | Equivalent to in-vehicle temperature | |||
| INT TEMP SEN | Ignition switch ON | Values depending on evaporator fin temperature | |||
| AMB SEN CAL | Ignition switch ON | Equivalent to ambient temperature | |||
| IN-VEH CAL | Ignition switch ON | Equivalent to in-vehicle temperature | |||
| INT TEMP CAL | Ignition switch ON | Values depending on evaporator fin temperature | |||
| ENG COOL TEMP | Ignition switch ON | Values depending on engine coolant temperature | |||
| DR SUNLOAD SEN | Ignition switch ON | Values depending on sunload (driver side) | |||
| PASS SUNLOAD SEN | Ignition switch ON | Values depending on sunload (passenger side) | |||
| DR SUNL SEN CAL | Ignition switch ON | Values depending on sunload (driver side) | |||
| PASS SUNL SEN CAL | Ignition switch ON | Values depending on sunload (passenger side) | |||
| BLOWER MOT VOLT | Engine: Run at idle after warming up | Active test (HVAC test): MODE | 1 4 V | ||
| Active test (HVAC test): MODE 2 | 4 V | ||||
| Active test (HVAC test): MODE 3 | 7 V | ||||
| Active test (HVAC test): MODE 4 | 7 V | ||||
| Active test (HVAC test): MODE 5 | 11.5 V | ||||
| Active test (HVAC test): MODE 6 | 11.5 V | ||||
| Active test (HVAC test): MODE 7 | 4 V | ||||
| VEHICLE SPEED | Turn drive wheels and compare CONSULT value with the speedometer indication. | Equivalent to speedometer reading | |||
| RELATIVE HUMIDITY(1) | Ignition switch ON | Values depending on relative humidity | |||
| AIR TEMP(1) | Ignition switch ON | Equivalent to air temperature around humidity sensor | |||
| DEW POINT TEMP(1) | Ignition switch ON | Values depending on dew point temperature | |||
| GLASS TEMP(1) | Ignition switch ON | Equivalent to windshield glass temperature | |||
| GAS SEN LEVEL(1) | Ignition switch ON | Values depending on contamination of ambient air | |||
| COMP RPM | Power switch ON | A/C switch: ON (Compressor operation status) |
Rotation speed of electric compressor | ||
| COMP INPUT POWER SIG | Power switch ON | A/C switch: ON (Compressor operation status) |
Power consumption value of electric compressor | ||
| COMP INPUT CRNT CHARGE | Power switch ON | A/C switch: ON (Compressor operation status) |
Input current value of electric compressor | ||
| COMP IPM TEMP SIG | Power switch ON | A/C switch: ON (Compressor operation status) |
Detection value of IPM temperature sensor inside electric compressor | ||
| COMP INPUT VOLT SIG | Power switch ON | A/C switch: ON (Compressor operation status) |
Input voltage value of electric compressor | ||
| COMP USAGE APPROVE PWR | Power switch ON | A/C switch: ON (Compressor operation status) |
5.1 kW | ||
| COMP DISCHR TMP OVRHEAT | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP IPM OVERHEAT | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP VOLT SATURATION | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP OVER CURRENT | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP OVER LOADED | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP LOW VOLT ERROR | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP HIGH VOLT ERROR | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMM ERROR HVAC→COMPR | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP IPM TEMP SEN ERROR | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP SHUNT SIG ERROR | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP ROM, RAM, AD ERROR | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP DISCHRG TEMP LIMIT | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP IPM TEMP LIMIT | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| COMP LOW SPEED OVR LOAD | Power switch ON | A/C switch: ON (Compressor operation status) |
OK | ||
| ENGINE On REQ | Power switch ON | A/C switch: ON (Compressor operation status) |
Engine on request signal on: ON Engine on request signal off: OFF |
||
| A/C PD CUT | Power switch ON | A/C switch: ON (Compressor operation status) |
Normal refrigerant pressure :OFF Malfunction of refrigerant pressure: OFF |
||
| HEATER NUP | Power switch ON | A/C switch: ON (Compressor operation status) |
HEATER NUP signal on: ON HEATER NUP signal off: OFF |
||
|
|||||