Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist .
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
EVAP control system pressure sensor Ground Voltage (V) Connector Terminal B73 3 Ground Approx. 5 Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B73 3 M107 107 Existed Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M7, B1
- Harness for open between ECM and EVAP control system pressure sensor
: Repair open circuit.
- CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Check sensor power supply 2 circuit. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: GO TO 12.
NO: Repair short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B73 1 M107 112 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 9.
NO: GO TO 8.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B1, M7
- Harness for open or short between EVAP control system pressure sensor and ECM
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AN SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B73 2 M107 102 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 11.
NO: GO TO 10.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B1, M7
- Harness for open or short between EVAP control system pressure sensor and ECM
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 12.
NO: Replace EVAP control system pressure sensor. Refer to "EXPLODED VIEW ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END