Operation Description
- Air inlet switches to recirculation when exhaust gas or outside odor is detected while FOREST switch is ON. After that, air inlet switches to fresh air intake when exhaust gas or outside odor becomes not detectable.
- Control status is displayed on "Forest Air Info" screen. Refer to "FOREST AIR SYSTEM: SWITCH NAME AND FUNCTION ".
NOTE:
- Sensitivity of exhaust gas/outside odor detecting sensor can be changed by "Outside/Inside Air Mix" in "Forest Air Setting" menu. Refer to "FOREST AIR SYSTEM: MENU DISPLAYED BY PRESSING EACH SWITCH ".
- Automatic intake control (exhaust gas/outside odor detecting mechanism) does not operate when ambient temperature is -2°C (28°F) or less. In this case, control is only for control of automatic air inlet of automatic air conditioning system.