Diagnosis Procedure
- PERFORM INITIALIZATION
- Perform initialization of BCM and reregistration of all Intelligent Keys using CONSULT.
- Start the engine.
Dose the engine start?
YES: INSPECTION END
NO: GO TO 2.
- CHECK DONGLE UNIT CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector and dongle unit connector.
- Check continuity between BCM harness connector and dongle unit harness connector.
BCM Dongle unit Continuity Connector Terminal Connector Terminal M120 24 M165 7 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M120 24 Not existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness.
- CHECK DONGLE UNIT GROUND CIRCUIT
Check continuity between dongle unit harness connector and ground.
Dongle unit Ground Continuity Connector Terminal M165 1 Existed Is the inspection result normal?
YES: Replace dongle unit.