Diagnosis Procedure
- INSPECTION START
Perform inspection in accordance with the procedure that confirms DTC.
Which procedure confirms DTC?
DTC confirmation procedure 1: GO TO 2.
DTC confirmation procedure 2: GO TO 6.
- CHECK DTC OF TCM
Check DTC in "Self Diagnostic Result" mode of "TCM" using CONSULT.
Is DTC detected?
YES: Perform the trouble diagnosis related to the detected DTC. Refer to "DTC INDEX ".
NO: GO TO 3.
- CHECK BCM INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between BCM harness connector and ground.
(+) (-) Condition Voltage (V) (Approx.) BCM Connector Terminal M123 102 Ground Selector lever P or N position 12 Other than above 0 Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 5.
- REPLACE BCM
- Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
: INSPECTION END
- CHECK BCM INPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector.
- Disconnect A/T assembly connector.
- Check continuity between A/T assembly harness connector and BCM harness connector.
A/T assembly BCM Continuity Connector Terminal Connector Terminal F61 9 M123 102 Existed - Check continuity between A/T assembly harness connector and ground.
A/T assembly Ground Continuity Connector Terminal F61 9 Not existed Is the inspection result normal?
YES: GO TO 11.
NO: Repair or replace harness.
- CHECK A/T SHIFT SELECTOR POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect A/T shift selector (detention switch) connector.
- Check voltage between A/T shift selector (detention switch) harness connector and ground.
(+) (-) Voltage (V) (Approx.) A/T shift selector (detention switch) Connector Terminal M137 7 Ground 12 Is the inspection result normal?
YES: GO TO 9.
NO: GO TO 7.
- CHECK A/T SHIFT SELECTOR POWER SUPPLY CIRCUIT
- Disconnect BCM connector.
- Check continuity between A/T shift selector (detention switch) harness connector and BCM harness connector.
A/T shift selector (detention switch) BCM Continuity Connector Terminal Connector Terminal M137 7 M123 104 Existed - Check continuity between A/T shift selector (detention switch) harness connector and ground.
A/T shift selector (detention switch) Ground Continuity Connector Terminal M137 7 Not existed Is the inspection result normal?
YES: GO TO 8.
NO: Repair or replace harness.
- REPLACE BCM
- Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
: INSPECTION END
- CHECK A/T SHIFT SELECTOR CIRCUIT
- Disconnect BCM connector and IPDM E/R connector.
- Check continuity between A/T shift selector (detention switch) harness connector and BCM harness connector.
A/T shift selector (detention switch) BCM Continuity Connector Terminal Connector Terminal M137 8 M120 37 Existed - Check continuity between A/T shift selector (detention switch) harness connector and ground.
A/T shift selector (detention switch) Ground Continuity Connector Terminal M137 8 Not existed Is the inspection result normal?
YES: GO TO 10.
NO: Repair or replace harness.
- CHECK A/T SHIFT SELECTOR (DETENTION SWITCH)
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 11.
NO: Replace A/T shift selector. Refer to "2WD: REMOVAL AND INSTALLATION " (2WD) or "AWD: REMOVAL AND INSTALLATION " (AWD).
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END