Diagnosis Procedure
- CHECK TRUNK KEY CYLINDER SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect trunk key cylinder switch connector.
- Check voltage between trunk key cylinder switch harness connector and ground.
(+) (-) Voltage (Approx.) Trunk key cylinder switch Connector Terminal T6 2 Ground 12 V Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 2.
- CHECK TRUNK KEY CYLINDER SWITCH SIGNAL CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and trunk key cylinder switch harness connector.
BCM Trunk key cylinder switch Continuity Connector Terminal Connector Terminal M121 41 T6 2 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M121 41 Not existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness.
- REPLACE BCM
- Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
- Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
: INSPECTION END
- CHECK TRUNK KEY CYLINDER SWITCH GROUND CIRCUIT
Check continuity between trunk key cylinder switch harness connector and ground.
Trunk key cylinder switch Ground Continuity Connector Terminal T6 1 Existed Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace harness.
- CHECK TRUNK KEY CYLINDER SWITCH
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 6.
NO: Replace trunk key cylinder switch.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END