Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- VVEL ACTUATOR MOTOR OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect VVEL control module harness connector.
- Disconnect VVEL actuator motor harness connector.
- Check the continuity between VVEL control module harness connector and VVEL actuator motor harness connector.
DTC No. VVEL control module VVEL actuator motor Continuity Bank Connector Terminal Connector Terminal P100A 1 E15 12 F48 1 Existed 2 Not existed 25 1 Not existed 2 Existed P100B 2 2 F49 1 Existed 2 Not existed 15 1 Not existed 2 Existed - Also check harness for short to ground and power.
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F40, E20
- Harness for open or short between VVEL actuator motor and VVEL control module
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK VVEL ACTUATOR MOTOR
Refer to "COMPONENT INSPECTION (VVEL ACTUATOR MOTOR) ".
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- REPLACE VVEL ACTUATOR SUB ASSEMBLY
- Replace VVEL actuator sub assembly.
- Go to
"SPECIAL REPAIR REQUIREMENT ".
: INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: GO TO 7.
NO: Repair or replace.
- REPLACE VVEL CONTROL MODULE
- Replace VVEL control module.
- Go to
"WORK PROCEDURE
".
: GO TO 8.
- PERFORM DTC CONFIRMATION PROCEDURE
- Turn ignition switch ON.
- Erase DTC.
- Perform DTC Confirmation Procedure.
See "DTC LOGIC ".
Is the DTC P100A or P100B displayed again?
YES: GO TO 9.
NO: INSPECTION END
- CHECK VVEL ACTUATOR SUB ASSEMBLY
Refer to "COMPONENT INSPECTION (VVEL ACTUATOR SUB ASSEMBLY) ".
Is the inspection result normal?
YES: GO TO 11.
NO: GO TO 10.
- REPLACE VVEL ACTUATOR SUB ASSEMBLY
- Replace VVEL actuator sub assembly.
- Go to
"SPECIAL REPAIR REQUIREMENT ".
: INSPECTION END
- CHECK VVEL LADDER ASSEMBLY
Refer to "INSPECTION ".
Is the inspection result normal?
YES: GO TO 13.
NO: GO TO 12.
- REPLACE CYLINDER HEAD, VVEL LADDER ASSEMBLY AND VVEL ACTUATOR SUB ASSEMBLY
- Replace cylinder head, VVEL ladder assembly and VVEL actuator sub assembly.
- Go to
"SPECIAL REPAIR REQUIREMENT ".
: INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
: INSPECTION END