Diagnosis Procedure
- 4WAS MAIN CONTROL UNIT
Check that there is no malfunction in 4WAS main control unit harness connector or disconnection.
Is the inspection result normal?
YES: Replace 4WAS main control unit. Refer to "REMOVAL AND INSTALLATION ".
- Before replacing 4WAS main control unit, record the self-diagnosis results (history). Refer to "SPECIAL REPAIR REQUIREMENT ".
NO: Repair or replace the harnesses and connectors. Refer to "PRECAUTIONS FOR HARNESS REPAIR ".