Removal and Installation: Removal
CAUTION:
- Never erase the memory (history) of self-diagnosis results when replacing 4WAS front control unit after diagnosis.
- Erase the memory of the self-diagnosis results (record) after printing out or recording all the values of "DATA MONITOR".
- Turn the ignition switch OFF.
- Remove the glove box. Refer to "REMOVAL AND INSTALLATION ".
- Remove the instrument lower panel RH. Refer to "REMOVAL AND INSTALLATION ".
- Disconnect 4WAS front control unit connectors.CAUTION: Disconnect 4WAS front control unit connectors 10 minutes after turning the ignition switch OFF.
- Remove the bolts of 4WAS front control unit.
- Remove the 4WAS front control unit.