Home >> Infiniti >> 2012 >> M37 Sport >> Repair and Diagnosis >> External Pages >> Different car >> Section 106 (Security Control System) >> System Description >> System >> INFINITI Vehicle Immobilizer System-NATS >> INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS: System Description >> Engine Start Operation When Intelligent Key Is Contacted To Push-Button Ignition Switch
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Engine Start Operation When Intelligent Key Is Contacted To Push-Button Ignition Switch

WARNING: This page is about a different car, the 2013 Infiniti M56 and 2013 Infiniti M37. However, it is still accessible from the selected car via links, so may be relevant.
  1. When brake pedal is depressed while selector lever is in the P position, BCM activates NATS antenna amp. that is located behind push-button ignition switch.
  2. When Intelligent Key (transponder built-in) backside is contacted to push-button ignition switch, BCM starts IVIS (NATS) ID verification between BCM and Intelligent Key (transponder built-in) via NATS antenna amp.
  3. When IVIS (NATS) ID verification result is OK, buzzer in combination meter sounds and BCM transmits the result to ECM.
  4. When push-button ignition switch is pressed, BCM turns ACC relay ON and transmits ignition power supply ON signal to IPDM E/R.
  5. IPDM E/R turns the ignition relay ON to start the ignition power supply.
  6. BCM detects that the selector lever position is P or N.
  7. BCM transmits starter request signal to IPDM E/R and turns the starter relay in IPDM E/R ON if BCM judges that the engine start condition* is satisfied.
  8. IPDM E/R turns the starter control relay ON when receiving the starter request signal.
  9. Power source is supplied to the starter motor through the starter relay and the starter control relay.
  10. When BCM receives feedback signal from ECM indicating that the engine is started, BCM transmits a stop signal to IPDM E/R and stops cranking by turning off the starter motor relay. (If engine start is unsuccessful, cranking stops automatically within 5 seconds.)

*: For the engine start condition, refer to "POWER SUPPLY POSITION CHANGE TABLE BY PUSH-BUTTON IGNITION SWITCH OPERATION " below.