Component Inspection
- CHECK HOOD SWITCH
- Turn ignition switch OFF.
- Disconnect hood switch connector.
- Check continuity between hood switch terminals.
Hood switch Condition Continuity Terminal 1 2 Hood switch Press Not existed Release Existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace hood lock (RH). Refer to "HOOD LOCK: REMOVAL AND INSTALLATION ".