Component Function Check
- CHECK OPERATION OF METER BUZZER
- Connect the CONSULT.
- Perform "LIGHT WARN ALM" in "ACTIVE TEST" of "BCM (BUZZER)".
Does meter buzzer beep?
YES: INSPECTION END
NO: GO TO 2.
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
Select the "Data Monitor" of "METER/M&A" and check the "BUZZER" monitor value.
"BUZZER"
Under the condition of buzzer input: On
Except above: Off
Is the inspection result normal?
YES: Replace combination meter.
NO: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".