Fail-Safe Control By DTC
Retractable hard top control unit performs fail-safe control when any DTC are detected.
| Display contents of CONSULT | Fail-safe | Cancellation | |
|---|---|---|---|
| U1000 | CAN COMM CIRCUIT | Inhibit retractable hard top operation. | Communication is normal |
| U1010 | CONTROL UNIT (CAN) | Inhibit retractable hard top operation. | Communication is normal |
| U0140 | LOCAL COMM-1 | Inhibit retractable hard top operation. | Communication is normal |
| U0215 | LOCAL COMM-1 | Inhibit retractable hard top operation. | Communication is normal |
| B1701 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Replace retractable hard top control unit. |
| B1702 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Replace retractable hard top control unit. |
| B1709 | ROOF SWITCH (OPEN) | Inhibit retractable hard top operation. | Detects roof open/close switch (OPEN) is OFF |
| B170A | ROOF SWITCH (CLOSE) | Inhibit retractable hard top operation. | Detects roof open/close switch (CLOSE) is OFF |
| B170B | ROOF SWITCH | Inhibit retractable hard top operation. | Detects roof open/close switch (OPEN/CLOSE) is OFF |
| B170C | TRUNK LINK SENSOR (LH) | Inhibit retractable hard top operation. | Detects normal value |
| B170D | TRUNK LINK SENSOR (RH) | Inhibit retractable hard top operation. | Detects normal value |
| B170F | SENSOR POWER SUPPLY | Inhibit retractable hard top operation. | Detects normal value |
| B1710 | LATCH STATUS SENSOR | Inhibit retractable hard top operation. | Detects normal value |
| B1711 | LATCH LOCK SENSOR | Inhibit retractable hard top operation. | Detects normal value |
| B1712 | TRUNK STATUS SENSOR | Inhibit retractable hard top operation. | Detects normal value |
| B1715 | ROOF STATUS SEN PWR | Inhibit retractable hard top operation. | Detects normal value |
| B1716 | PS STATUS SEN (DRAW) | Inhibit retractable hard top operation. | Detects normal value |
| B1718 | PS STATUS SEN (ROTA) | Inhibit retractable hard top operation. | Detects normal value |
| B1719 | ROOF STATUS SEN | Inhibit retractable hard top operation. | Detects normal value |
| B171A | HYDRAULIC PMP (LH) | Inhibit retractable hard top operation. | Detects normal value |
| B171B | HYDRAULIC PMP (RH) | Inhibit retractable hard top operation. | Detects normal value |
| B171C | SWITCHING VALVE 1 | Inhibit retractable hard top operation. | Detects normal value |
| B171D | SWITCHING VALVE 2 | Inhibit retractable hard top operation. | Detects normal value |
| B171E | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B171F | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1720 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1721 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1722 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1723 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1724 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1725 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1726 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1728 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1729 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B172A | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B172B | ROOF STATE SIG (AUDIO) | Inhibit retractable hard top operation. | Detects normal value |
| B172D | ROOF WARNING BUZZER | Inhibit retractable hard top operation. | Detects normal value |
| B172E | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B172F | REAR PWR WINDOW (LH) | Inhibit retractable hard top operation. | Detects normal value |
| B1730 | REAR PWR WINDOW (RH) | Inhibit retractable hard top operation. | Detects normal value |
| B1731 | HYDRAULIC STATE 1 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1732 | HYDRAULIC STATE 2 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1733 | HYDRAULIC STATE 3 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1734 | HYDRAULIC STATE 4 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1735 | HYDRAULIC STATE 5 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1736 | HYDRAULIC STATE 6 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1737 | HYDRAULIC STATE 7 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1738 | HYDRAULIC STATE 8 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1739 | HYDRAULIC STATE 9 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B173A | HYDRAULIC STATE 10 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B173B | HYDRAULIC STATE 11 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B173C | HYDRAULIC STATE 12 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B173D | HYDRAULIC STATE 13 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B173E | HYDRAULIC STATE 14 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B173F | HYDRAULIC STATE 15 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1740 | HYDRAULIC STATE 16 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1741 | HYDRAULIC STATE 17 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1742 | HYDRAULIC STATE 18 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1743 | HYDRAULIC STATE 19 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1744 | HYDRAULIC STATE 20 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1745 | HYDRAULIC STATE 21 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1746 | HYDRAULIC STATE 22 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1747 | P SHELF (DRAW) STATE 1 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1748 | P SHELF (DRAW) STATE 2 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1749 | P SHELF (DRAW) STATE 3 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B174A | P SHELF (DRAW) STATE 4 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B174B | P SHELF (DRAW) STATE 5 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B174C | P SHELF (DRAW) STATE 6 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B174D | P SHELF (ROT) STATE 1 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B174E | P SHELF (ROT) STATE 2 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B174F | P SHELF (ROT) STATE 3 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1750 | P SHELF (ROT) STATE 4 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1751 | ROOF LATCH STATE 1 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1752 | ROOF LATCH STATE 2 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1753 | ROOF LATCH STATE 3 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1754 | FLIPPER DOOR STATE 1 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1755 | FLIPPER DOOR STATE 2 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1756 | FLIPPER DOOR STATE 3 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1757 | FLIPPER DOOR STATE 4 | Inhibit retractable hard top operation. | Turn ignition switch OFF |
| B1758 | THERMO PROTECTION | Inhibit retractable hard top operation. | It is not in thermo protection area (Refer to "RETRACTABLE HARD TOP SYSTEM: SYSTEM DESCRIPTION ") |
| B175C | PWR SOURCE (ROOF) | Inhibit retractable hard top operation. | Power source is 11.4 (V) or more for 0.5 second |
| B175D | PWR SOURCE (ROOF) | Inhibit retractable hard top operation. | Power source is 14.5 (V) or more for 4 seconds |
| B175E | PWR SOURCE (WINDOW) | Inhibit retractable hard top operation and rear power window operation. | Power source (power window) is 9.5 (V) or less |
| B175F | PWR SOURCE (WINDOW) | Inhibit retractable hard top operation and rear power window operation. | Power source (power window) is 15.5 (V) or more |
| B1760 | ROOF CONTROL UNIT | Inhibit rear window defogger operation. | Detects normal value |
| B1761 | ROOF CONTROL UNIT | Inhibit retractable hard top operation. | Detects normal value |
| B1762 | ROOF STATE | Inhibit retractable hard top operation. | Detects normal value |
| B1763 | HYDRAULIC STATE | Inhibit retractable hard top operation. | Detects normal value |
| B1764 | ROOF LATCH STATE | Inhibit retractable hard top operation. | Detects normal value |
| B1765 | FLIPPER DOOR STATE | Inhibit retractable hard top operation. | Detects normal value |