| B00A0 |
OCCUPANT SENS [Occupant Classification System (Subfault)] |
[ABNORMAL VOLTAGE] |
Power supply malfunction of occupant classification sensor |
- Connection malfunction or short circuit to power supply of harness or connector
- Internal malfunction of occupant classification sensor
- Internal malfunction of air bag diagnosis sensor unit
|
| [UNIT MALFUNC] |
Malfunction of occupant classification sensor |
- Connection malfunction of harness and connector
- Internal malfunction of occupant classification sensor
- Internal malfunction of air bag diagnosis sensor unit
|
| OCCUPANT SENS C/U [Occupant Classification System (Subfault)] |
[RESET] |
Reset malfunction of occupant classification sensor control unit |
- Connection malfunction of harness and connector
- Internal malfunction of occupant classification sensor control unit
- Internal malfunction of air bag diagnosis sensor unit
|
| [UNIT MALFUNC] |
Malfunction of occupant classification sensor control unit |
- Connection malfunction or open circuit of harness and connector
- Internal malfunction of occupant classification sensor control unit
- Internal malfunction of air bag diagnosis sensor unit
|
| [COMM ERR] |
- Communication malfunction of occupant classification sensor control unit
- Communication blank of occupant classification sensor control unit
|
| [UNDEFINED] |
Undefined status of occupant classification sensor control unit |