Diagnostic Test
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connections M95, E46. Refer to Ground Inspection in CIRCUIT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace ground connection.
- VVEL ACTUATOR MOTOR OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect VVEL control module harness connector.
- Disconnect VVEL actuator motor harness connector.
- Check the continuity between VVEL control module harness connector and VVEL actuator motor harness connector.
DTC No. VVEL control module VVEL actuator motor Continuity Bank Connector Terminal Connector Terminal P100A 1 E15 12 F48 1 Existed 2 Not existed 25 1 Not existed 2 Existed P100B 2 2 F49 1 Existed 2 Not existed 15 1 Not existed 2 Existed - Also check harness for short to ground and power.
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 3 .
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F1, E3
- Harness for open or short between VVEL actuator motor and VVEL control module
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK VVEL ACTUATOR MOTOR
Refer to COMPONENT INSPECTION (VVEL ACTUATOR MOTOR) .
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
GO TO STEP 5 .
- REPLACE VVEL ACTUATOR SUB ASSEMBLY
- Replace VVEL actuator sub assembly.
- Go to SPECIAL REPAIR REQUIREMENT .
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace.
- REPLACE VVEL CONTROL MODULE
- Replace VVEL control module. Refer to COMPONENT PARTS LOCATION .
- Go to SPECIAL REPAIR REQUIREMENT .
GO TO STEP 8 .
- PERFORM DTC CONFIRMATION PROCEDURE
- Turn ignition switch ON.
- Erase DTC.
- Perform DTC Confirmation Procedure.
See DTC LOGIC .
Is the DTC P100A or P100B displayed again?
YES
GO TO STEP 9 .
NO
INSPECTION END
- CHECK VVEL ACTUATOR SUB ASSEMBLY
Refer to COMPONENT INSPECTION (VVEL ACTUATOR SUB ASSEMBLY) .
Is the inspection result normal?
YES
GO TO STEP 11 .
NO
GO TO STEP 10 .
- REPLACE VVEL ACTUATOR SUB ASSEMBLY
- Replace VVEL actuator sub assembly.
- Go to SPECIAL REPAIR REQUIREMENT .
INSPECTION END
- CHECK VVEL LADDER ASSEMBLY
Refer to INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 13 .
NO
GO TO STEP 12 .
- REPLACE CYLINDER HEAD, VVEL LADDER ASSEMBLY AND VVEL ACTUATOR SUB ASSEMBLY
- Replace cylinder head (refer to DISASSEMBLY AND ASSEMBLY ), VVEL ladder assembly and VVEL actuator sub assembly.
- Go to SPECIAL REPAIR REQUIREMENT .
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END