Work Procedure
Initialize the system if any of the following work has been done. Refer to Work Procedure .
- When control unit replaced.
- Electric power supply to power window switch or motor is interrupted by blown (open) fuse or disconnection and connection of the negative terminal of battery, etc.
- Removal and installation of regulator assembly.
- Power supply to the power window main switch or power window motor is cut off by the removal
of battery terminal or if the battery fuse is blown (open).
- Disconnection and connection of power window main switch harness connector.
- Removal and installation of motor from regulator assembly.
- Operation of regulator assembly as an independent unit.
- Removal and installation of door glass.
- Removal and installation of door glass run.
The following specified operations can not be performed under the non-initialized condition.
- Auto-up operation
- Anti-pinch function
- STEP 1
Fully open the door window.
GO TO 2.
- STEP 2
Place a piece of wood near fully closed position.
GO TO 3.
- STEP 3
Close door glass completely with AUTO-UP.
GO TO 4.
- STEP 4
Check the following conditions
- Check that glass lowers for approximately [front: 150 mm (5.9 in), rear: 116 mm (4.5 in)] without pinching piece of wood and stops.
- Check that glass does not rise not when operating the power window main switch while lowering.
CAUTION:- Perform initial setting when auto-up operation or anti-pinch function does not operate normally.
- Check that AUTO-UP operates before inspection when system initialization is performed.
- Do not check with hands and other body parts because they may be pinched. Do not get pinched.
- It may switch to fail-safe mode if open/close operation is performed continuously without full close.
Perform initial setting in that situation. Refer to Work Procedure .
END