Individual Function Within The System
The electric shift sensor has 8 non-contact sensors (Hall IC) built in. Each sensor switches ON/OFF according to the selector lever position.
SELECTOR LEVER position judgement Table
|
Selector lever position |
Electric shift sensor |
|||||||
|
No. 1 |
No. 2 |
No. 3 |
No. 4 |
No. 5 |
No. 6 |
No. 7 |
No. 8 |
|
|
R |
ON |
ON |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
|
Nr |
OFF |
ON |
ON |
ON |
OFF |
OFF |
OFF |
OFF |
|
H |
OFF |
OFF |
ON |
ON |
ON |
ON |
OFF |
OFF |
|
Nd |
OFF |
OFF |
OFF |
OFF |
ON |
ON |
ON |
OFF |
|
D/M |
OFF |
OFF |
OFF |
OFF |
OFF |
OFF |
ON |
ON |