DTC Detection Logic
|
DTC |
Display item |
Malfunction detected condition |
Possible cause |
|
C160A |
HEAT PROTECTION |
When the steering wheel is operated excessively and the interior temperature of the power steering system reaches 118 deg. C (244.4 deg. F) or more. (Protection function)
NOTE:
Although the hydraulic pump electric power steering system warning lamp turns ON, this is not a system malfunction. The state returns to normal after stopping steering operation and waiting until the system interior temperature drops to 90 deg. C (194 deg. F) or less.
|
The protection of the hydraulic pump electric power steering system |