Models with Around View Monitor System
- CHECK BACK-UP LAMP RELAY
- Turn ignition switch OFF.
- Remove back-up lamp relay.
- Check the continuity between back-up lamp relay terminals as per the following condition.
Back-up lamp relay
Condition
Continuity
Terminal
3
5
12 V direct current supply between terminals 1 and 2
Existed
No current supply
Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace back-up lamp relay.