Models with Around View Monitor System
- CHECK AROUND VIEW MONITOR CONTROL UNIT POWER SUPPLY AND GROUND CIRCUIT
Check around view monitor control unit power supply and ground circuit. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair malfunctioning parts.
- CHECK REAR CAMERA POWER SUPPLY OUTPUT CIRCUIT (CHECK FOR SHORT CIRCUIT)
- Disconnect around view monitor control unit connector and rear camera connector.
- Check whether or not continuity between around view monitor control unit harness connector and ground is normal.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B51
50
Not existed
Is the inspection result normal?
YES
GO TO 3.
NO
Repair the harnesses or connectors.
- CHECK REAR CAMERA POWER SUPPLY 1
- Connect around view monitor control unit connector.
- Turn ignition switch ON.
- Check whether or not voltage between around view monitor control unit harness connectors is normal.
Around view monitor control unit
Reference value
(Approx.)
Connector
Terminals
(+)
(-)
Terminal
B51
50
52
6.0 V
Is the inspection result normal?
YES
GO TO 4.
NO
Replace around view monitor control unit. Refer to AROUND VIEW MONITOR CONTROL UNIT : Removal & Installation .
- CHECK REAR CAMERA POWER SUPPLY 2
- Turn ignition switch OFF.
- Connect rear camera connector.
- Turn ignition switch ON.
- Check whether or not voltage between around view monitor control unit harness connectors is normal.
Around view monitor control unit
Reference value
(Approx.)
Connector
Terminals
(+)
(-)
Terminal
B51
50
52
6.0 V
Is the inspection result normal?
YES
GO TO 5.
NO
Replace rear camera. Refer to REAR CAMERA : Removal & Installation .
- CHECK FRONT CAMERA POWER SUPPLY OUTPUT CIRCUIT (CHECK FOR SHORT CIRCUIT)
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector and front camera connector.
- Check whether or not continuity between around view monitor control unit harness connector and ground is normal.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B51
68
Not existed
Is the inspection result normal?
YES
GO TO 6.
NO
Repair the harnesses or connectors.
- CHECK FRONT CAMERA POWER SUPPLY 1
- Connect around view monitor control unit connector.
- Turn ignition switch ON.
- Check whether or not voltage between around view monitor control unit harness connectors is normal.
Around view monitor control unit
Reference value
(Approx.)
Connector
Terminals
(+)
(-)
Terminal
B51
68
70
6.0 V
Is the inspection result normal?
YES
GO TO 7.
NO
Replace around view monitor control unit. Refer to AROUND VIEW MONITOR CONTROL UNIT : Removal & Installation .
- CHECK FRONT CAMERA POWER SUPPLY 2.
- Turn ignition switch OFF.
- Connect front camera connector.
- Turn ignition switch ON.
- Check whether or not voltage between around view monitor control unit harness connectors is normal.
Around view monitor control unit
Reference value
(Approx.)
Connector
Terminals
(+)
(-)
Terminal
B51
68
70
6.0 V
Is the inspection result normal?
YES
GO TO 8.
NO
Replace front camera. Refer to FRONT CAMERA : Removal & Installation .
- CHECK SIDE CAMERA RH POWER SUPPLY OUTPUT CIRCUIT (CHECK FOR SHORT CIRCUIT)
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector and door mirror (driver side) connector.
- Check whether or not continuity between around view monitor control unit harness connector and ground is normal.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B51
62
Not existed
Is the inspection result normal?
YES
GO TO 9.
NO
Repair the harnesses or connectors.
- CHECK SIDE CAMERA RH POWER SUPPLY 1
- Connect around view monitor control unit connector.
- Turn ignition switch ON.
- Check whether or not voltage between around view monitor control unit harness connectors is normal.
Around view monitor control unit
Reference value
(Approx.)
Connector
Terminals
(+)
(-)
Terminal
B51
62
64
6.0 V
Is the inspection result normal?
YES
GO TO 10.
NO
Replace around view monitor control unit. Refer to AROUND VIEW MONITOR CONTROL UNIT : Removal & Installation .
- CHECK SIDE CAMERA RH POWER SUPPLY 2
- Turn ignition switch OFF.
- Connect door mirror (driver side) connector.
- Turn ignition switch ON.
- Check whether or not voltage between around view monitor control unit harness connectors is normal.
Around view monitor control unit
Reference value
(Approx.)
Connector
Terminals
(+)
(-)
Terminal
B51
62
64
6.0 V
Is the inspection result normal?
YES
GO TO 11.
NO
Replace side camera RH. Refer to SIDE CAMERA : Removal & Installation .
- CHECK SIDE CAMERA LH POWER SUPPLY OUTPUT CIRCUIT (CHECK FOR SHORT CIRCUIT)
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector and door mirror (passenger side) connector.
- Check whether or not continuity between around view monitor control unit harness connector and ground is normal.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B51
56
Not existed
Is the inspection result normal?
YES
GO TO 12.
NO
Repair the harnesses or connectors.
- CHECK SIDE CAMERA LH POWER SUPPLY 1
- Connect around view monitor control unit connector.
- Turn ignition switch ON.
- Check whether or not voltage between around view monitor control unit harness connectors is normal.
Around view monitor control unit
Reference value
(Approx.)
Connector
Terminals
(+)
(-)
Terminal
B51
56
58
6.0 V
Is the inspection result normal?
YES
GO TO 13.
NO
Replace around view monitor control unit. Refer to AROUND VIEW MONITOR CONTROL UNIT : Removal & Installation .
- CHECK SIDE CAMERA LH POWER SUPPLY 2
- Turn ignition switch OFF.
- Connect door mirror (passenger side) connector.
- Turn ignition switch ON.
- Check whether or not voltage between around view monitor control unit harness connectors is normal.
Around view monitor control unit
Reference value
(Approx.)
Connector
Terminals
(+)
(-)
Terminal
B51
56
58
6.0 V
Is the inspection result normal?
YES
Replace around view monitor control unit. Refer to AROUND VIEW MONITOR CONTROL UNIT : Removal & Installation .
NO
Replace side camera LH. Refer to SIDE CAMERA : Removal & Installation .