DTC Detection Logic
The heated oxygen sensor 2 has a much longer switching time between rich and lean than the air fuel ratio (A/F) sensor 1. The oxygen storage capacity of the three way catalyst 1 causes the longer switching time.
MALFUNCTION A
To judge malfunctions of heated oxygen sensor 2, ECM monitors whether the voltage is unusually high during various driving conditions such as fuel cut.
MALFUNCTION B
To judge malfunctions of heated oxygen sensor 2, ECM monitors whether the minimum voltage of sensor is sufficiently low during various driving conditions such as fuel cut.
|
DTC No. |
CONSULT screen terms (Trouble diagnosis content) |
DTC detecting condition |
|
|
P0136 |
HO2S2 (B1) (O2 sensor circuit bank 1 sensor 2) |
A |
An excessively high voltage from the sensor is sent to ECM. |
|
B |
The minimum voltage from the sensor is not reached to the specified voltage. |
||