Confirmation Procedure
- PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5 deg.C (41 deg.F) or more.
GO TO 2.
- PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- On CONSULT screen, select "ENGINE">>"Data Monitor".
- Make sure that "FUEL T/TMP SE" is more than 0 deg.C (32 deg.F).
- Start engine and wait at least 20 seconds.
- Check 1st trip DTC.
With GST
- Start engine and warm it up to normal operating temperature.
- Set voltmeter probes to ECM harness connector terminals as per the following.
ECM
Connector
+
-
Terminal
E152
173
200
- Make sure that the voltage is less than 4.2 V.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and wait at least 20 seconds.
- Check 1st trip DTC.
Is DTC P0452 detected?
YES
Refer to DTC Diagnosis Procedure .
NO
To check malfunction symptom before repair: Refer to Inspection .
NO
Confirmation after repair: INSPECTION END