Detailed Flow
- PRELIMINARY INSPECTION
Perform the preliminary inspection. Refer to Diagnosis Procedure .
GO TO 2.
- INSPECTION WITH CHARGE WARNING LAMP (PUSH-BUTTON IGNITION SWITCH IS PRESSED ON)
When push-button ignition switch is pressed ON.
Does the charge warning lamp illuminate?
YES
GO TO 3.
NO
Replace generator. Refer to Removal and Installation .
- INSPECTION WITH CHARGE WARNING LAMP (IDLING)
Start the engine and run it at idle
Does the charge warning lamp turn OFF?
YES
GO TO 4.
NO
GO TO 5.
- INSPECTION WITH CHARGE WARNING LAMP (ENGINE AT 2, 500 RPM)
Increase and maintain the engine speed at 2, 500 RPM.
Does the charge warning lamp illuminate?
YES
GO TO 5.
NO
Inspection End.
- MEASURE "B" TERMINAL VOLTAGE
Start engine. With engine running at 2, 500 RPM, measure "B" terminal voltage.
What voltage does the measurement result show?
Less than 13.0 V
GO TO 6.
More than 16.0 V
Replace generator. Refer to Removal and Installation .
- "B" TERMINAL CIRCUIT INSPECTION
Check "B" terminal circuit. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
Replace generator. Refer to Removal and Installation .
NO
Repair as needed.