Diagnosis Procedure

  1. INSPECTION START 

    Confirm the detected malfunction (A or B). Refer to DTC Description .

    Which malfunction is detected?

    A

    GO TO 2.

    B

    GO TO 7.

  2. CHECK HEATED OXYGEN SENSOR 2 CONNECTOR 
    1. Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
    2. Check that water is not inside connectors.

    There is no leakage.

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace malfunctioning part.

  3. CHECK HO2S2 GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
    4. Check the continuity between HO2S2 harness connector and ECM harness connector.

      HO2S2

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      E39

      1

      F52

      76

      Existed

    5. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair or replace malfunctioning part.

  4. CHECK HO2S2 INPUT SIGNAL CIRCUIT 
    1. Check the continuity between HO2S2 harness connector and ECM harness connector.

      HO2S2

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      E39

      2

      F52

      77

      Existed

    2. Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.

      HO2S2

      --

      Continuity

      Connector

      Terminal

      E39

      2

      Ground

      Not existed

      ECM

      --

      Continuity

      Connector

      Terminal

      F52

      77

      Ground

      Not existed

    3. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 5.

    NO

    Repair or replace malfunctioning part.

  5. CHECK HEATED OXYGEN SENSOR 2 

    Refer to Component Inspection .

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    GO TO 6.

  6. REPLACE HEATED OXYGEN SENSOR 2 

    Replace heated oxygen sensor 2. Refer to Exploded View .

    CAUTION:
    • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
    • Before installing new oxygen sensor, clean exhaust system threads.

    INSPECTION END

  7. PERFORM AIR FUEL RATIO INITIAL LEARNING 
    1. Start engine and warm it up to the normal operating temperature.
    2. Clear the air fuel ratio initial learning. Refer to Work Procedure .
    3. Run engine for at least 10 minutes at idle speed.

    Is the 1st trip DTC P0172 detected? Is it difficult to start engine?

    YES

    Perform trouble diagnosis for DTC P0172. Refer to Diagnosis Procedure .

    NO

    GO TO 8.

  8. CHECK HEATED OXYGEN SENSOR 2 GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
    4. Check the continuity between HO2S2 harness connector and ECM harness connector.

      HO2S2

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      E39

      1

      F52

      76

      Existed

    5. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 9.

    NO

    Repair or replace malfunctioning part.

  9. CHECK HO2S2 INPUT SIGNAL CIRCUIT 
    1. Check the continuity between HO2S2 harness connector and ECM harness connector.

      HO2S2

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      E39

      2

      F52

      77

      Existed

    2. Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.

      HO2S2

      --

      Continuity

      Connector

      Terminal

      E39

      2

      Ground

      Not existed

      ECM

      --

      Continuity

      Connector

      Terminal

      F52

      77

      Ground

      Not existed

    3. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 10.

    NO

    Repair or replace malfunctioning part.

  10. CHECK HEATED OXYGEN SENSOR 2 

    Refer to Component Inspection .

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    GO TO 11.

  11. REPLACE HEATED OXYGEN SENSOR 2 

    Replace heated oxygen sensor 2. Refer to Exploded View .

    CAUTION:
    • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
    • Before installing new oxygen sensor, clean exhaust system threads.

    INSPECTION END