How To Set
CONSULT
Select "CLEAN SW SET" in "Work support" mode of "HVAC".
|
Work support items |
Display |
Setting |
|
CLEAN SW SET |
Mode1 |
Initial setting |
|
Mode2 |
Setting 1 |
|
|
Mode3 (Initial status) |
Setting 2 |
|
|
Mode4 |
Setting 3 |
|
Setting |
Setting status |
|
Initial setting |
When the auto intake switch is ON, the A/C switch is also turned ON in synchronization with the auto intake switch. Control of the auto intake switch is functional even when the A/C switch is turned OFF. |
|
Setting 1 |
When the auto intake switch is ON, the A/C switch is not turned ON in synchronization with the auto intake switch. Control of the auto intake switch is functional even when the A/C switch is turned OFF. |
|
Setting 2 |
When the auto intake switch is ON, the A/C switch is also turned ON in synchronization with the auto intake switch. When the A/C switch is turned OFF, the auto intake switch is turned OFF in synchronization with the A/C switch. |
|
Setting 3 |
Auto intake switch can be turned ON only when A/C switch is ON. When the A/C switch is turned OFF, the auto intake switch is turned OFF in synchronization with the A/C switch. |