Home >> Infiniti >> 2021 >> QX50 Essential, 4WD >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heater & Air Conditioning Control System (Diagnostics, Service Information) >> Basic Inspection >> System Setting >> Exhaust Gas/outside Odor Detecting Sensor Sensitivity Adjustment Function >> How To Set
April 5, 2026: LEMON Manuals is launched! Read the announcement.

How To Set

SYMBOL CONSULT

Select "GAS SENSOR ADJUSTMENT" in "Work support" mode of "HVAC".

Work support items

Display

Setting

GAS SENSOR ADJUSTMENT

2

More sensitive setting than display 1 (REC earlier than display 1.)

1

More sensitive setting than normal setting (REC earlier than normal operation.)

0 (initial status)

Normal

-1

Less sensitive setting than normal setting (REC later than normal operation.)

-2

Less sensitive setting than display -1 (REC later than display -1.)

NOTE: When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of WORK SUPPORT may be cancelled.