Consult Data Monitor Reference Values
|
Monitor item |
Condition |
Value/Status |
|
|
AMB TEMP SEN |
Ignition switch ON |
Equivalent to ambient temperature |
|
|
IN-VEH TEMP |
Ignition switch ON |
Equivalent to in-vehicle temperature |
|
|
INT TEMP SEN |
Ignition switch ON |
Equivalent to evaporator fin temperature |
|
|
SUNLOAD SEN |
Ignition switch ON |
Equivalent to sunload amount |
|
|
AMB SEN CAL |
Ignition switch ON |
Equivalent to ambient temperature |
|
|
IN-VEH CAL |
Ignition switch ON |
Equivalent to in-vehicle temperature |
|
|
INT TEMP CAL |
Ignition switch ON |
Equivalent to evaporator fin temperature |
|
|
SUNL SEN CAL |
Ignition switch ON |
Equivalent to sunload amount |
|
|
COMP REQ SIG |
Engine: Run at idle after warming up |
A/C switch: ON (Compressor operation status) |
On |
|
A/C switch: OFF |
Off |
||
|
COMP ECV DUTY |
Engine: Run at idle after warming up |
Active test (HVAC test): MODE 1 |
100% |
|
Active test (HVAC test): MODE 2 |
100% |
||
|
Active test (HVAC test): MODE 3 |
50% |
||
|
Active test (HVAC test): MODE 4 |
0% |
||
|
Active test (HVAC test): MODE 5 |
0% |
||
|
Active test (HVAC test): MODE 6 |
100% |
||
|
Active test (HVAC test): MODE 7 |
100% |
||
|
FAN REQ SIG |
Engine: Run at idle after warming up |
Front blower motor: ON |
On |
|
Front blower motor: OFF |
Off |
||
|
FAN DUTY |
Engine: Run at idle after warming up |
Front blower motor: ON |
25 - 79 |
|
Front blower motor: OFF |
0 |
||
|
XM |
Ignition switch ON |
Value according to target air flow temperature (driver side) |
|
|
ENG COOL TEMP |
Ignition switch ON |
Equivalent to engine coolant temperature |
|
|
VEHICLE SPEED |
Turn drive wheels and compare CONSULT value with the speedometer indication. |
Equivalent to speedometer reading |
|
|
BLOWER MOT VOLT |
NOTE:
This item is indicated, but not monitored.
|
0 V |
|
|
GAS SEN LEVEL* |
Ignition switch ON |
Values depending on contamination of ambient air |
|
*: With ACCS