Fail-Safe Function
If a communication error exists between the A/C auto amp. and AV control unit for 30 seconds or longer, air conditioning is controlled under the following conditions:
When ambient temperature is less than 3 deg. C (37 deg. F) and engine coolant temperature is less than 56 deg. C (133 deg. F)
|
Compressor |
: ON |
|
Air outlet |
: DEF |
|
Air inlet |
: FRE (Fresh air intake) |
|
Blower fan speed |
: AUTO |
|
Set temperature |
: Setting before communication error occurs |
When ambient temperature is 3 deg. C (37 deg. F) or more, or engine coolant temperature is 56 deg. C (133 deg. F) or more
|
Compressor |
: ON |
|
Air outlet |
: AUTO |
|
Air inlet |
: FRE (Fresh air intake) |
|
Blower fan speed |
: AUTO |
|
Set temperature |
: Setting before communication error occurs |
NOTE:
When ambient temperature is less than 3 deg. C (37 deg. F) and engine coolant temperature is less than 56 deg. C (133 deg. F), low coolant temperature starting control do not operated.