LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2021 >> QX50 Essential, 4WD >> Repair and Diagnosis >> Electrical >> Body Electrical >> Power Control System (IPDM E/R) >> System Description >> Diagnosis System (IPDM E/R) >> CONSULT Function (IPDM E/R) >> Data Monitor
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Data Monitor

Monitor Item [Unit]

Description

REVERSE SIGNAL [Open/Close]

Indicates condition of transmission range switch R (Reverse) position.

IGN RELAY [Open/Close]

Indicates condition of ignition relay-1.

PUSH SW [Open/Close]

Indicates condition of push-button ignition switch.

NEUTRAL SW [Open/Close]

NOTE: The item is indicated, but not monitored.

INTERLOCK/PNP SW [Open/Close]

Indicates condition of transmission range switch P (Park) and N (Neutral) positions.

OIL PRESSURE SW [On/Off]

Indicates condition of oil pressure switch.

LED H/L RH STATUS [Open/Close]

Indicates condition of RH LED headlamp status.

LED H/L LH STATUS [Open/Close]

Indicates condition of LH LED headlamp status.

HOOD SW [Open/Close]

Indicates condition of hood switch.

COMPRESSOR [OFF/ON]

Indicates condition of A/C compressor.

HORN RELAY [OFF/ ON]

Indicates condition of horn relay.

COOLING FAN [OFF/ ON]

Indicates condition of cooling fan 1 status.

FRONT WIPER HI/LO RELAY [OFF/ON]

Indicates condition of front wiper high relay.

FRONT WIPER RELAY [OFF/ON]

Indicates condition of front wiper relay.

IGN RELAY OFF STATUS [OFF/ON]

Indicates condition of ignition relay-1 OFF status.

IGN RELAY ON STATUS [OFF/ON]

Indicates condition of ignition relay-1 ON status.

STARTER RELAY [OFF/ON]

Indicates condition of starter relay.

COMP ECV DUTY [%]

Indicates condition of A/C compressor.

COOLING FAN RELAY 2 [%]

Indicates condition of cooling fan 2 (PWM) status.

FR FOG LAMP LH [%]

Indicates condition of front fog lamp LH.

FR FOG LAMP RH [%]

Indicates condition of front fog lamp RH.

PARKING LAMP [%]

Indicates condition of parking lamp.

TAIL LAMP LH [%]

Indicates condition of tail lamp LH.

TAIL LAMP RH [%]

Indicates condition of tail lamp RH.

DAYTIME RUNNING LIGHT LH [%]

Indicates condition of daytime running light LH.

DAYTIME RUNNING LIGHT RH [%]

Indicates condition of daytime running light RH.

HEADLAMP (HI) LH [%]

Indicates condition of headlamp high beam LH.

HEADLAMP (HI) RH [%]

Indicates condition of headlamp high beam RH.

HEADLAMP (LO) LH [%]

Indicates condition of headlamp low beam LH.

HEADLAMP (LO) RH [%]

Indicates condition of headlamp low beam RH.

A/C RELAY STUCK [NG/OK]

Indicates condition of A/C relay.

A/C RELAY [Off/On]

Indicates condition of A/C relay.

COMP ECV STATUS [NG/OK]

Indicates condition of A/C compressor.

VEHICLE SECURITY HORN [Off/On]

Indicates condition of horn relay.

BATTERY CURRENT SENSOR [OK/NG]

Displays the battery current sensor malfunction diagnosis status judged by IPDM E/R.

FRONT FOG LAMP [Off/On]

Indicates condition of front fog lamps.

COMP ECV CURRENT [A]

Indicates condition of A/C compressor current.

BATTERY VOLTAGE [V]

Indicates condition of battery voltage.

COOLING FAN DUTY [%]

Indicates condition of cooling fans.

HOOD SW (CAN) [OPEN/CLOSE]

Indicates condition of hood switch.

FRONT WIPER [STOP/LOW/HIGH]

Indicates condition of front wiper motor.

FR WIPER STOP POSITION [STOP P/ACTIVE P]

Indicates condition of front wiper motor stop.

HEADLAMP (HI) [Off/On]

Indicates condition of headlamp high beams.

HEADLAMP (LO) [Off/On]

Indicates condition of headlamp low beams.

IGNITION RELAY STATUS [Off/On]

Indicates condition of ignition relay-1.

IGN RELAY MONITOR [Off/On]

Indicates condition of ignition relay-1 feedback.

IGNITION POWER SUPPLY [Off/On]

Indicates condition of ignition relay-1.

INTERLOCK/PNP SW (CAN) [Off/On]

Indicates condition of transmission range switch P (Park) and N (Neutral) positions.

NEUTRAL SWITCH (CAN) [Off/On/NG]

NOTE: The item is indicated, but not monitored.

PUSH-BUTTON IGN SW (CAN) [Off/On]

Indicates condition of push-button ignition switch.

TAIL LAMP [Off/On]

Indicates condition of tail lamps.

REVERSE SIGNAL (CAN) [Off/On]

Indicates condition of transmission range switch R (Reverse) position.

ST&ST CONT RELAY STATUS [Off/ST R On]

Indicates condition of starter cut and starter relays.

STARTER MOTOR STATUS [Off/On]

Indicates condition of starter motor.

STARTER RELAY (CAN) [LOW/HIGH]

Indicates condition of starter relay.

IPDM NOT SLEEP [NO RDY/RDY]

Indicates condition of IPDM E/R sleep status.

AFTER COOLING TIME [No request/0.5min/1.0min/1.5min/2.0min/2.5min/3.0min/3.5min/4min/5min/6min/8min/10min/12min/14min/16min]

NOTE: The item is indicated, but not monitored.

AFTER COOLING SPEED [0/0.25/0.4/0.55/0.7/0.78/0.85/1]

NOTE: The item is indicated, but not monitored.

COOLING FAN TYPE [Renault/NISSAN]

NOTE: The item is indicated, but not monitored.

COMPRESSOR REQ1 [Off/On]

Indicates condition of A/C compressor request.

VHCL SECURITY HORN REQ [Off/On]

Indicates condition of horn relay request.

DTRL REQ [Off/On]

Indicates condition of daytime running light request.

SLEEP/WAKE UP [WAKEUP/SLEEP]

Indicates condition of IPDM E/R sleep/wake.

CRANKING ENABLE-TCM [NG/OK]

Indicates condition of crank enable from TCM.

CRANKING ENABLE-ECM [NG/OK]

Indicates condition of crank enable from ECM.

CAN DIAGNOSIS [NG/OK]

Indicates condition of CAN diagnosis.

FRONT FOG LAMP REQ [Off/On]

Indicates condition of front fog lamp request.

PASSING REQ [Off/On]

Indicates condition of headlamp flash to pass request.

HIGH BEAM REQ [Off/On]

Indicates condition of headlamp high beam request.

HORN CHIRP [Off/On]

Indicates condition of horn relay request.

COOLING FAN REQ [%]

Indicates condition of cooling fan request.

ENGINE STATUS [STOP/RUN/IDLING]

Indicates condition of engine status.

TURN SIGNAL REQ [Off/LH/RH]

Indicates condition of turn signal request.

FR WIPER REQ [RETURN/LOW/HIGH]

Indicates condition of front wiper motor request.

SHIFT POSITION [P/R/N/D/L]

Indicates condition of transmission range switch positions.

LOW BEAM REQ [Off/On]

Indicates condition of headlamp low beam request.

POSITION LIGHT REQ [Off/On]

Indicates condition of parking lamp request.

COMPRESSOR REQ2 [Off/On]

Indicates condition of A/C compressor request.

IGNITION SW [Off/On]

Indicates condition of ignition switch.

VEHICLE SPEED (METER) [mph/km/h]

Indicates vehicle speed.

STARTER OPERATION COUNT [Numerical]

Displays number of times starter motor is energized.

H/P F/PUMP OPERATN COUNT [Numerical]

Displays number of times high pressure fuel pump is energized.

P LAMP CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for the parking lamp circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB P LAMP CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of parking lamp circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB P LAMP CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of parking lamp circuit.

DTRL LH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for daytime running light (left) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB DTRL LH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of daytime running light (left) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB DTRL LH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of daytime running light (left) circuit.

DTRL RH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for daytime running light (right) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB DTRL RH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of daytime running light (right) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB DTRL RH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of daytime running light (right) circuit.

F FOG LH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for front fog lamp (left) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB F FOG LH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of front fog lamp (left) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB F FOG LH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of front fog lamp (left) circuit.

F FOG RH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for front fog lamp (right) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB F FOG RH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of front fog lamp (right) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB F FOG RH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of front fog lamp (right) circuit.

HL (HI) LH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for headlamp (HI) (left) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB HL (HI) LH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of headlamp (HI) (left) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB HL (HI) LH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of headlamp (HI) (left) circuit.

HL (HI) RH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for headlamp (HI) (right) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB HL (HI) RH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of headlamp (HI) (right) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB HL (HI) RH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of headlamp (HI) (right) circuit.

HL (LO) LH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for headlamp (LO) (left) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB HL (LO) LH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of headlamp (LO) (left) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB HL (LO) LH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of headlamp (LO) (left) circuit.

HL (LO) RH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for headlamp (LO) (right) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB HL (LO) RH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of headlamp (LO) (right) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB HL (LO) RH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of headlamp (LO) (right) circuit.

T LAMP LH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for tail lamp (left) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB T LAMP LH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of tail lamp (left) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB T LAMP LH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of tail lamp (left) circuit.

T LAMP RH CIRC MALFUNCTN [0 - 1]

Monitors number of times smart FET reaches retry upper limit for tail lamp (right) circuit.

NOTE: When number of retry counts is 20, count is 1.

NMB T LAMP RH CIRC RETRY [0 - 20]

Monitors number of times smart FET permits retry of tail lamp (right) circuit.

NOTE: When number of short circuit counts is 5 and the ignition switch OFF to ON operation is detected, count is 1.

NMB T LAMP RH CIRC SHORT [0 - 5]

Monitors number of times smart FET detects over current of tail lamp (right) circuit.