"L" Circuit Shorted Test

  1. Turn ignition off. Disconnect ABS control unit harness connector located behind right kick panel. Turn ignition on. If CHARGE warning light illuminates, replace ABS control unit with a known good unit and repeat test. If CHARGE warning light does not illuminate, go to next step.
  2. Turn ignition off. Repair short to ground in generator harness connector terminal No. 3 (White/Blue wire) to CHARGE warning light. See Fig 1 .
Fig 1: Identifying Generator Harness Connector Terminals
G93H00346Courtesy of AMERICAN HONDA MOTOR CO., INC.