Circuit Description
The ECM memory contains the shift programs for the NORMAL and POWER patterns, "2" , "L" and the lock-up patterns. Following the programs corresponding to the signals from the pattern select switch, the PNP switch and other various sensors, the ECM switches the solenoid valves ON and OFF, and controls the transmission gear change and the lock-up clutch operation.