Inspection Procedure
WARNING: This page is about a different car, the 2003 Lexus LX 470. However, it is still accessible from the selected car via links, so may be relevant.
- Check ECU-IG1 and AM1 fuse.
CHECK:
Check continuity of ECU-IG1 and AM1 fuse.
OK:
- Continuity
- NG : Replace faulty fuse.
- OK : GO TO NEXT STEP
- Check voltage between terminals BECU, SIG, BDR and GND of power window master switch connector.
PREPARATION:
Turn the ignition switch OFF.
CHECK:
Measure the voltage between terminals BECU, SIG, BDR and GND.
OK:
- Voltage: 10-14V
- OK : Proceed to next circuit inspection shown on problem symptoms table (See PROBLEM SYMPTOMS TABLE ).
- No: Go to next step
- Check wire harness and connector between power window master switch and body ground (See
HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE
).
- NG : Repair or replace wire harness or connector.
- OK : Proceed to next circuit inspection shown on problem symptoms table (See PROBLEM SYMPTOMS TABLE ).