Inspection Procedure
WARNING: This page is about a different car, the 2003 Lexus LX 470. However, it is still accessible from the selected car via links, so may be relevant.
- Check Mayday switch (Overhead J/B).
PREPARATION:
Disconnect the Mayday switch connector.
CHECK:
Check that the continuity exists between terminals of Mayday switch when each switch is pressed.
OK:
DIAGNOSTIC CHARTSwitch position Tester connection Specified condition Service Play back Record 1 - 2 Continuity Emergency Volume UP Volume DOWN 2-3 Continuity - NG : Replace the Mayday switch (overhead J/B).
- OK: Go to next step
- Check for open and short circuit in harness and connector between telephone ECU (Mayday ECU) and Mayday switch (over head J/B) (See
HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE
).
- NG : Replace or harness or connector.
- OK : Check and replace telephone ECU (Mayday ECU) (See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE ).