Typical Enabling Conditions
All:
TYPICAL ENABLING CONDITIONS
| Monitor runs whenever following DTCs are not present | P0115 - P0118 (ECT sensor) P2009 - P2010 (DC motor for SCV) P2014, P2016 - P2017 (SCV position sensor) |
P2004 (Intake manifold runner control open stuck):
TYPICAL ENABLING CONDITIONS
| ECT | -10°C (14°F) or more |
| IAT | -10°C (14°F) or more |
| Engine switch | ON |
| Battery voltage | 8 V or more |
P2006 (Intake manifold runner control closed stuck):
TYPICAL ENABLING CONDITIONS
| ECT | -10°C (14°F) or more |
| IAT | -10°C (14°F) or more |
| Engine switch | ON |